Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/77498
Title: GRAding of functional and anatomical response to DExamethasone implant in patients with Diabetic Macular Edema: GRADE-DME Study
Authors: Patricio J. Rodríguez-Valdés
Matus Rehak
Dinah Zur
Anna Sala-Puigdollers
Samantha Fraser-Bell
Marco Lupidi
Jay Chhablani
Zafer Cebeci
Inês Laíns
Voraporn Chaikitmongkol
Adrian T. Fung
Mali Okada
Jan Darius Unterlauft
Lital Smadar
Anat Loewenstein
Matias Iglicki
Catharina Busch
Authors: Patricio J. Rodríguez-Valdés
Matus Rehak
Dinah Zur
Anna Sala-Puigdollers
Samantha Fraser-Bell
Marco Lupidi
Jay Chhablani
Zafer Cebeci
Inês Laíns
Voraporn Chaikitmongkol
Adrian T. Fung
Mali Okada
Jan Darius Unterlauft
Lital Smadar
Anat Loewenstein
Matias Iglicki
Catharina Busch
Keywords: Multidisciplinary
Issue Date: 1-Dec-2021
Abstract: To analyze functional and anatomical response patterns to dexamethasone (DEX) implant in diabetic macular edema (DME), to describe proportion of responders and non-responders, and to propose a new DME grading system. Retrospective, multicenter, observational cohort study. Naïve and non-naïve DME patients were treated with DEX, with visual acuity (VA) ≥ 0.2 logMAR and central subfield thickness (CST) of ≥ 300 µm. Functional and anatomical responses were graded after 2 and 4 months, and categorized as early and stable improvement, early and progressive improvement, pendular response, delayed improvement, and persistent non-response. 417 eyes were included (175 treatment naïve eyes). Compared to non-naïve eyes, naïve eyes showed a very good functional response (VA gain ≥ 10 letters) more frequently after 2 and 4 months (56% and 57% [naïve] vs. 33% and 28% [non-naïve], p < 0.001). A VA gain < 5 letters (non-response) after 2 and 4 months was seen in 18% and 16% of naïve eyes, and in 49% and 53% of non-naïve eyes (p < 0.001). A lack of anatomical response was rare in both groups, but more frequently in non-naïve eyes (12% vs. 4%, p = 0.003). Functionally and anatomically, naïve eyes showed most frequently an early and stable improvement (functionally: 77/175 44%; anatomically: 123/175 eyes, 70%). Most non-naïve eyes experienced no significant improvement functionally (97/242 eyes, 40%), despite a mostly early and stable improvement anatomical response pattern (102/242 eyes, 42%). Functional but not anatomical response patterns were influenced by baseline VA. Naïve and non-naïve eyes show different functional and anatomical response patterns to DEX implant. Functional non-responders are rare in naïve eyes, whereas anatomical non-response is unusual in both groups.
URI: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85101933430&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/77498
ISSN: 20452322
Appears in Collections:CMUL: Journal Articles