Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/76402
Title: Deep Contrast and Companion Detection Using the EvWaCo Test Bed Equipped with an Achromatic Focal Plane Mask and an Adjustable Inner Working Angle
Authors: Mary Angelie Alagao
Adithep Kawinkij
Christophe Buisset
Apirat Prasit
Thierry Lépine
Yves Rabbia
Anthony Berdeu
Oric Thiébaut
Maud Langlois
Michel Tallon
Supachai Awiphan
Eugene Semenko
Pakakaew Rittipruk
David Mkrtichian
Apichat Leckngam
Griangsak Thuammasorn
Pimol Kaewsamoeta
Anuphong Inpan
Teerawat Kuha
Auychai Laoyang
Worawat Somboonchai
Suchinno Kanthum
Saran Poshyachinda
Boonrucksar Soonthornthum
Authors: Mary Angelie Alagao
Adithep Kawinkij
Christophe Buisset
Apirat Prasit
Thierry Lépine
Yves Rabbia
Anthony Berdeu
Oric Thiébaut
Maud Langlois
Michel Tallon
Supachai Awiphan
Eugene Semenko
Pakakaew Rittipruk
David Mkrtichian
Apichat Leckngam
Griangsak Thuammasorn
Pimol Kaewsamoeta
Anuphong Inpan
Teerawat Kuha
Auychai Laoyang
Worawat Somboonchai
Suchinno Kanthum
Saran Poshyachinda
Boonrucksar Soonthornthum
Keywords: Earth and Planetary Sciences;Physics and Astronomy
Issue Date: 1-May-2021
Abstract: The evanescent wave coronagraph uses the principle of frustrated total internal reflection (FTIR) to suppress the light coming from the star and study its close environment. Its focal plane mask is composed of a lens and a prism placed in contact with each other to produce the coronagraphic effect. In this paper, we present the experimental results obtained using an upgraded focal plane mask of the Evanescent Wave Coronagraph (EvWaCo). These experimental results are also compared to the theoretical performance of the coronagraph obtained through simulations. Experimentally, we reach a raw contrast equal to a few 10-4 at a distance equal to 3 λ/D over the full I band (λ c = 800 nm, Δλ/λ ≈ 20%) and equal to 4 λ/D over the full R band (λ c = 650 nm, Δλ/λ ≈ 23%) in unpolarized light. However, our simulations show a raw contrast close to 10-4 over the full I band and R band at the same distance, thus confirming the theoretical achromatic advantage of the coronagraph. We also verify the stability of the mask through a series of contrast measurements over a period of 8 months. Furthermore, we measure the sensitivity of the coronagraph to the lateral and longitudinal misalignment of the focal plane mask and to the lateral misalignment of the Lyot stop.
URI: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85108181241&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/76402
ISSN: 00046256
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.