Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/71495
Title: Multiwalled Carbon Nanotubes in Microfluidic Chip for the Separation of X- And Y-Sperm Based on a Photolithography Technique
Authors: Chalinee Phiphatanaphiphop
Komgrit Leksakul
Rungrueang Phatthanakun
Wutthikrai Busayaporn
Chatree Saiyasombat
Pat Phothongkam
Md Mohosin Rana
Hiroaki Suzuki
Authors: Chalinee Phiphatanaphiphop
Komgrit Leksakul
Rungrueang Phatthanakun
Wutthikrai Busayaporn
Chatree Saiyasombat
Pat Phothongkam
Md Mohosin Rana
Hiroaki Suzuki
Keywords: Engineering
Issue Date: 1-Oct-2020
Abstract: © 1992-2012 IEEE. This study examined the performance of a microfluidic device for sperm separation assuming that X- and Y-sperm have different surface electrical charges. The proposed microfluidic chip was first tested with electrically charged particles, namely TiO2-coated polystyrene (PS) beads, to mimic spermatozoa. Negatively charged TiO2-coated PS beads were fabricated in a simple and efficient manner. These beads were characterised using X-ray diffraction, tungsten scanning electron microscopy with energy-dispersive X-ray spectroscopy mode, and X-ray absorption spectroscopy to determine the reason for the persistence of the negative surface charge. The fabricated TiO2-coated PS beads were partly coated in mixed forms of amorphous Ti4+, which caused a sustained negative charge on the surface after fabrication. The microfluidic device was simulated to obtain an optimal structure for fabrication. Negatively charged TiO2-coated PS beads were tested in designed microfluidic devices. Detailed structures for microfluidic device design with integrated microelectrodes were fabricated using a photolithographic technique, and the finished device was tested with PS beads. Based on PS-bead separation, a microfluidic device with a 150μ m microchannel and 100μ m distance between electrodes was the best performing prototype at 87.07% with a confidence level of 95%. Commercial positively and negatively charged PS beads were tested in the selected design for additional validation. Finally, sperm separation using the proposed device was conducted; the specially designed microfluidic device with multiwalled carbon nanotubes was fabricated, and the proposed device showed a X- and Y-sperm separation accuracy of 74.62%.
URI: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85092560340&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/71495
ISSN: 19410158
10577157
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.