Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/70339
Title: | LC-MS Quantification of Malondialdehyde-Dansylhydrazine Derivatives in Urine and Serum Samples |
Authors: | Kostya Kartavenka Parinya Panuwet Volha Yakimavets Churdsak Jaikang Kanitarin Thipubon Priya Esilda D'Souza Dana Boyd Barr P. Barry Ryan |
Authors: | Kostya Kartavenka Parinya Panuwet Volha Yakimavets Churdsak Jaikang Kanitarin Thipubon Priya Esilda D'Souza Dana Boyd Barr P. Barry Ryan |
Keywords: | Chemical Engineering;Chemistry;Environmental Science;Pharmacology, Toxicology and Pharmaceutics |
Issue Date: | 2-Apr-2020 |
Abstract: | © The Author(s) 2020. Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com. We developed a robust analytical method for quantification of malondialdehyde (MDA) in urine and serum samples using dansylhydrazine (DH) as a derivatizing reagent. The derivatization procedure was partially carried out using an autosampler injection program to minimize errors associated with the low-volume addition of reagents and was optimized to yield a stable hydrazone derivative of MDA and its labeled d2-MDA analogue. The target MDA-DH derivatives were separated on an Agilent Zorbax Eclipse Plus Phenyl-Hexyl (3.0 × 100 mm, 3.5 μm) column. The mass-to-charge ratios of the target derivatives [(M+H)+ of 302 and 304 for MDA-DH and d2-MDA-DH, respectively] were analyzed in single ion monitoring mode using a single quadrupole mass spectrometer operated under positive electrospray ionization. The method limits of quantification were 5.63 nM (or 0.405 ng/mL) for urine analysis and 5.68 nM (or 0.409 ng/mL) for serum analysis. The quantification range for urine analysis was 5.63-500 nM (0.405-36.0 ng/mL) while the quantification range for serum analysis was 5.68-341 nM (0.409-24.6 ng/mL). The method showed good relative recoveries (98-103%), good accuracies (92-98%), and acceptable precisions (relative standard deviations 1.8-7.3% for inter-day precision; 1.8-6.1% for intra-day precision) as observed from the repeat analysis of quality control samples prepared at different concentrations. The method was used to measure MDA in individual urine samples (n = 287) and de-identified archived serum samples (n = 22) to assess the overall performance of the method. The results demonstrated that our method is capable of measuring urinary and serum levels of MDA, allowing its future application in epidemiologic investigations. |
URI: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85086884756&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/70339 |
ISSN: | 19452403 |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.