Title: Flow Injection Amperometric System Coupled with a Well-Plate for Fast Screening of Total Antioxidant Capacity
Authors: Puttaporn Klayprasert
Jaroon Jakmunee
Authors: Puttaporn Klayprasert
Jaroon Jakmunee
Keywords: Biochemistry, Genetics and Molecular Biology;Chemistry;Medicine
Issue Date: 13-Aug-2018
Abstract: © 2017 Taylor & Francis. A flow injection (FI) system with an amperometric detection in combination with a 96-well-plate has been developed for high throughput screening of total antioxidant capacity. It is based on the reaction between dichromate and antioxidants Chromium reducing antioxidant capacity (CHROMAC) assay. Antioxidant reduces dichromate leading to a decrease of dichromate concentration, in which reacts further with triiodide reagent. The slow reaction between antioxidant and dichromate takes place in parallel in a 96-well microplate, with the reaction time sufficiently long to reach steady state conditions. Microliter volumes of the remaining dichromate solution were manually injected into the FI amperometric system. Reaction with iodide in acidic medium produces triiodide which undergoes electrochemical reduction on a glassy carbon working electrode at 200 mV versus a Ag/AgCl reference electrode. The decrease of electrical current was directly proportional to the antioxidant capacity. The optimum conditions have been achieved as follow: 160 mg L−1of potassium dichromate, pH of dichromate solution of 2.82, 0.005 mol L−1of potassium iodide, 0.20 mol L−1of hydrochloric acid, and 3.0 mL min−1total flow rate. The developed method was applied for the determination of total antioxidant capacity of tea and herbal infusions and fruit juice samples. The results obtained indicated that the developed method had good correlation with the batch CHROMAC spectrophotometric method and 1,1-diphenyl-2-picrylhydrazyl scavenging assay. The proposed method provides fast and high throughput analysis, convenient operation, and low consumption of chemical reagents and samples.
URI: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85045135639&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/58210
ISSN: 1532236X
00032719
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.