Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/57731
Title: Asia-Pacific consensus statement on the optimal use of high-sensitivity troponin assays in acute coronary syndromes diagnosis: Focus on hs-TnI
Authors: Jack Wei Chieh Tan
Carolyn S.P. Lam
Sazzli Shahlan Kasim
Tar Choon Aw
Joel M. Abanilla
Wei Ting Chang
Van Phuoc Dang
Maria Iboleon-Dy
Sari Sri Mumpuni
Arintaya Phommintikul
Manh Cuong Ta
Punkiat Topipat
Kai Hang Yiu
Louise Cullen
Authors: Jack Wei Chieh Tan
Carolyn S.P. Lam
Sazzli Shahlan Kasim
Tar Choon Aw
Joel M. Abanilla
Wei Ting Chang
Van Phuoc Dang
Maria Iboleon-Dy
Sari Sri Mumpuni
Arintaya Phommintikul
Manh Cuong Ta
Punkiat Topipat
Kai Hang Yiu
Louise Cullen
Keywords: Medicine
Issue Date: 1-Apr-2017
Abstract: Objective High-sensitivity troponin (hs-Tn) assays need to be applied appropriately to improve diagnosis and patient outcomes in acute coronary syndromes (ACS). Methods Experts from Asia Pacific convened in 2015 to provide data-driven consensus-based, region-specific recommendations and develop an algorithm for the appropriate incorporation of this assay into the ACS assessment and treatment pathway. Results Nine recommendations were developed by the expert panel: (1) troponin is the preferred cardiac biomarker for diagnostic assessment of ACS and is indicated for patients with symptoms of possible ACS; (2) hs-Tn assays are recommended; (3) serial testing is required for all patients; (4) testing should be performed at presentation and 3 hours later; (5) gender-specific cut-off values should be used for hs-Tn I assays; (6) hs- Tn I level >10 times the upper limit of normal should be considered to rule in a diagnosis of ACS; (7) dynamic change >50% in hs-Tn I level from presentation to 3- hour retest identifies patients at high risk for ACS; (8) where only point-of-care testing is available, patients with elevated readings should be considered at high risk, while patients with low/undetectable readings should be retested after 6 hours or sent for laboratory testing and (9) regular education on the appropriate use of troponin tests is essential. Conclusions We propose an algorithm that will potentially reduce delays in discharge by the accurate rule out of non-ACS patients within 3 hours. Appropriate research should be undertaken to ensure the efficacy and safety of the algorithm in clinical practice, with the long-term goal of improvement of care of patients with ACS in Asia Pacific.
URI: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85017503890&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/57731
ISSN: 17591104
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.