Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/77178
Title: Comparative dosimetry of brachytherapy treatment planning between a volume-based plan by CT and a point-based plan by TAUS in CT datasets for brachytherapy
Authors: Chaiyaporn Pintakham
Ekkasit Tharavichitkul
Somsak Wanwilairat
Wannapha Nobnop
Authors: Chaiyaporn Pintakham
Ekkasit Tharavichitkul
Somsak Wanwilairat
Wannapha Nobnop
Keywords: Medicine
Issue Date: 1-Jan-2021
Abstract: Aim: To evaluate comparative dosimetry of brachytherapy treatment planning between a volume-based plan by computed tomography (CT) and a point-based plan by transabdominal ultrasound (TAUS) in CT datasets for brachytherapy. Materials and methods: From 2019 to 2021, 59 different datasets of CT images were collected from 38 patients treated by intracavitary brachytherapy with tandem ovoid or tandem ring applicators. At that time, TAUS was performed to prevent uterine perforation and to evaluate topography of the cervix during application. In volume-based planning by CT, the target dose was used to keep the dose at 90% of high-risk clinical target volume (HR-CTV), to give a dose of at least 7Gy, while in the point-based plan by TAUS, the target dose was used to keep the minimum dose to eight cervix reference points (measured by TAUS), to give a dose of at least 7Gy. The doses to targets and organs at risk were evaluated and compared between volume-based planning by CT and the point-based plan by TAUS. Results: Of 59 fractions, a tandem ovoid applicator was used in 48 fractions (81·3%). In the volume-based plan by CT, the mean doses to HR-CTV(D90), intermediate-risk clinical target volume (IR-CTV)(D90), bladder(D2cc), rectum(D2cc) and sigmoid colon(D2cc) were 7·0, 3·9, 4·9, 2·9 and 3·3 Gy, respectively, while in the point-based plan by TAUS, the mean doses to HR-CTV(D90), IR-CTV(D90), bladder(D2cc), rectum(D2cc) and sigmoid colon(D2cc) were 8·2, 4·6, 5·9, 3·4 and 3·9 Gy, respectively. The percentages of mean dose differences between TAUS and CT of HR-CTV(D90), IR-CTV(D90), bladder(D2cc), rectum(D2cc) and sigmoid colon(D2cc) were 17·7, 19·5, 20·5, 19·5, 21·3 and 19·8%, respectively. With the target dose to the point-based plan by TAUS (7 Gy to the cervix reference points), this was close to D98 of HR-CTV with a mean percentage of difference of 0·6%. Findings: The point-based plan by TAUS showed higher values to targets and organs at risk than the volume-based plan by CT. With the point-based plan by TAUS, it was close to D98 of HR-CTV.
URI: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85120958578&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/77178
ISSN: 14671131
14603969
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.