Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/75806
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPakornswit Sathongdejwisiten_US
dc.contributor.authorKritsada Pruksaphonen_US
dc.contributor.authorAkarin Intaramaten_US
dc.contributor.authorPisinee Aiumuraien_US
dc.contributor.authorNitat Sookrungen_US
dc.contributor.authorKavi Ratanabanangkoonen_US
dc.contributor.authorJoshua D. Nosanchuken_US
dc.contributor.authorSirida Youngchimen_US
dc.date.accessioned2022-10-16T07:02:47Z-
dc.date.available2022-10-16T07:02:47Z-
dc.date.issued2021-01-01en_US
dc.identifier.issn20754418en_US
dc.identifier.other2-s2.0-85106522136en_US
dc.identifier.other10.3390/diagnostics11050758en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85106522136&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/75806-
dc.description.abstractThe aim of this study was to develop a novel lateral flow immunochromatoghaphic strip test (ICT) for detecting cryptococcal polysaccharide capsular antigens using only a single specific monoclonal antibody, mAb 18B7. The mAb 18B7 is a well characterized antibody that specifically binds repeating epitopes displayed on the cryptococcal polysaccharide glucuronoxylomannan (GXM). We validated the immunoreactivities of mAb 18B7 against capsular antigens of different cryptococcal serotypes. The mAb 18B7 ICT was constructed as a sandwich ICT strip and the antibody serving in the mobile phase (colloidal gold conjugated mAb 18B7) to bind one of the GXM epitopes while the stationary phase antibody (immobilized mAb18B7 on test line) binding to other remaining unoccupied epitopes to generate a positive visual readout. The lower limit of detection of capsular antigens for each of the Cryptococcus serotypes tested was 0.63 ng/mL. No cross-reaction was found against a panel of antigens isolated from cultures of other pathogenic fungal, except the crude antigen of Trichosporon sp. with the lower limit of detection of 500 ng/mL (~800 times higher than that for cryptococcal GXM). The performance of the mAb 18B7 ICT strip was studied using cerebrospinal fluid (CSF) and serum and compared to commercial diagnostic kits (latex agglutination CALAS and CrAg IMMY). The sensitivity, specificity and accuracy of the mAb18B7 ICT with CSF from patients with confirmed cryptococcal meningitis were 92.86%, 100% and 96.23%, respectively. No false positives were observed with samples from non-cryptococcosis patients. With serum samples, the mAb 18B7 ICT gave a sensitivity, specificity and accuracy of 96.15%, 97.78% and 96.91%, respectively. Our results show that the mAb 18B7 based ICT was reliable, reproducible, and cost-effective as a point-of-care immunodiagnostic test for cryptococcosis. The mAb 18B7 ICT may be particularly useful in countries where commercial kits are not available or affordable.en_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.titleA novel, inexpensive in-house immunochromatographic strip test for cryptococcosis based on the cryptococcal glucuronoxylomannan specific monoclonal antibody 18b7en_US
dc.typeJournalen_US
article.title.sourcetitleDiagnosticsen_US
article.volume11en_US
article.stream.affiliationsChulabhorn Research Instituteen_US
article.stream.affiliationsSiriraj Hospitalen_US
article.stream.affiliationsMahidol Universityen_US
article.stream.affiliationsAlbert Einstein College of Medicine of Yeshiva Universityen_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.