Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/75567
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPiyanat Issarangkura Na Ayutthayaen_US
dc.contributor.authorChonnipa Yeerumen_US
dc.contributor.authorKullapon Kesonkanen_US
dc.contributor.authorKanokwan Kiwfoen_US
dc.contributor.authorKate Grudpanen_US
dc.contributor.authorNorio Teshimaen_US
dc.contributor.authorHiroya Murakamien_US
dc.contributor.authorMonnapat Vongbooten_US
dc.date.accessioned2022-10-16T07:00:50Z-
dc.date.available2022-10-16T07:00:50Z-
dc.date.issued2021-09-01en_US
dc.identifier.issn14203049en_US
dc.identifier.other2-s2.0-85115414642en_US
dc.identifier.other10.3390/molecules26185720en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85115414642&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/75567-
dc.description.abstractA monolithic rod of polyurethane foam–[4-(2-pyridylazo) resorcinol] (PUF–PAR) as a simple chemical sensor for lead assays with smartphone detection and image processing was developed. With readily available simple apparatus such as a plastic cup and a stirrer rod, the monolithic PUF rod was synthesized in a glass tube. The monolithic PUF–PAR rod could be directly loaded by standard/sample solution without sample preparation. A one-shot image in G/B value from a profile plot in ImageJ for a sample with triplicate results via a single standard calibration approach was obtained. A linear single standard calibration was: [G/B value] = −0.038[µg Pb2+] + 2.827, R2 = 0.95 for 10–30 µg Pb2+ with a limit of quantitation (LOQ) of 33 µg L−1. The precision was lower than 15% RSD. The proposed method was tested by an assay for Pb2+ contents in drinking water samples from Bangkok. The results obtained by the proposed method agree with those of ICP-OES and with 100– 120% recovery, demonstrating that the method is useful for screening on-site water monitoring.en_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectChemistryen_US
dc.subjectPharmacology, Toxicology and Pharmaceuticsen_US
dc.titleLead assays with smartphone detection using a monolithic rod with 4-(2-pyridylazo) resorcinolen_US
dc.typeJournalen_US
article.title.sourcetitleMoleculesen_US
article.volume26en_US
article.stream.affiliationsAichi Institute of Technologyen_US
article.stream.affiliationsKing Mongkut's University of Technology Thonburien_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.