Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/70269
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKanokwan Kiwfoen_US
dc.contributor.authorWasin Wongwilaien_US
dc.contributor.authorTadao Sakaien_US
dc.contributor.authorNorio Teshimaen_US
dc.contributor.authorKate Grudpanen_US
dc.date.accessioned2020-10-14T08:26:44Z-
dc.date.available2020-10-14T08:26:44Z-
dc.date.issued2020-01-01en_US
dc.identifier.issn14203049en_US
dc.identifier.other2-s2.0-85082796138en_US
dc.identifier.other10.3390/molecules25071666en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85082796138&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/70269-
dc.description.abstract© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). A mono-segmented sequential injection lab-at-valve (SI-LAV) system for the determination of albumin, glucose, and creatinine, three key biomarkers in diabetes screening and diagnosis, was developed as a single system for multi-analyte analysis. The mono-segmentation technique was employed for in-line dilution, in-line single-standard calibration, and in-line standard addition. This made adjustments to the sample preparation step easy unlike the batch-wise method. The results showed that the system could be used for both fast reaction (albumin) and slow reaction (glucose with enzymatic reaction and creatinine). In the case of slow reaction, the analysis time could be shortened by using the reaction rate obtained with the SI-LAV system. This proposed system is for cost-effective and downscaling analysis, which would be applicable for small hospitals and clinics in remote places with a small number of samples but relatively fast screening would be needed.en_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectChemistryen_US
dc.subjectPharmacology, Toxicology and Pharmaceuticsen_US
dc.titleDetermination of albumin, glucose, and creatinine employing a single sequential injection lab-at-valve with mono-segmented flow system enabling in-line dilution, in-line single-standard calibration, and in-line standard additionen_US
dc.typeJournalen_US
article.title.sourcetitleMoleculesen_US
article.volume25en_US
article.stream.affiliationsAichi Institute of Technologyen_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.