Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/68508
Full metadata record
DC FieldValueLanguage
dc.contributor.authorChanhathai Nunchaien_US
dc.contributor.authorSupatra Sirichotiyakulen_US
dc.contributor.authorTheera Tongsongen_US
dc.date.accessioned2020-04-02T15:28:38Z-
dc.date.available2020-04-02T15:28:38Z-
dc.date.issued2020-01-01en_US
dc.identifier.issn14470756en_US
dc.identifier.issn13418076en_US
dc.identifier.other2-s2.0-85079875293en_US
dc.identifier.other10.1111/jog.14222en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85079875293&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/68508-
dc.description.abstract© 2020 Japan Society of Obstetrics and Gynecology Aim: To identify the optimal cutoff of mean corpuscular volume (MCV) for screening of alpha-thalassemia 1 trait. Methods: The database of pregnant women who attended antenatal care clinic at Department of Obstetrics and Gynecology, Chiang Mai University during January 1st, 2015 to December 31st, 2017 was accessed and reviewed. A total of 1264 cases who had MCV ≤80 fL and met the inclusion criteria were enrolled to the study. Cases with hemoglobin level ≤10.0 gm/dL, iron deficiency anemia, chronic medical diseases and other types of thalassemia trait except alpha-thalassemia 1 trait were excluded. Results: After exclusion, 438 cases were available for analysis. Of them, 139 were alpha-thalassemia 1 trait. Based on the receiver operating characteristic curves, the best cutoff value of MCV for screening of alpha-thalassemia 1 trait was ≤76.15 fL, giving 100% sensitivity, and 60.9% specificity with the area under curve of 0.925. Compared to the conventional cutoff (≤80 fL), the new cutoff gave much less false positive tests (117 vs 299 cases), whereas capability to detect alpha-thalassemia 1 trait was the same. Conclusion: With the new MCV cutoff (≤76.15 fL) as a secondary cutoff for screening alpha-thalassemia 1 carrier, a substantial number of positive cases requiring DNA analysis could be avoided without compromising the detection efficacy.en_US
dc.subjectMedicineen_US
dc.titleOptimal cutoff of mean corpuscular volume (MCV) for screening of alpha-thalassemia 1 traiten_US
dc.typeJournalen_US
article.title.sourcetitleJournal of Obstetrics and Gynaecology Researchen_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.