Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/68468
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Daehun Kang | en_US |
dc.contributor.author | Uten Yarach | en_US |
dc.contributor.author | Myung Ho In | en_US |
dc.contributor.author | Erin M. Gray | en_US |
dc.contributor.author | Joshua D. Trzasko | en_US |
dc.contributor.author | Hang Joon Jo | en_US |
dc.contributor.author | Yunhong Shu | en_US |
dc.contributor.author | John Huston | en_US |
dc.contributor.author | Matt A. Bernstein | en_US |
dc.date.accessioned | 2020-04-02T15:27:56Z | - |
dc.date.available | 2020-04-02T15:27:56Z | - |
dc.date.issued | 2020-07-01 | en_US |
dc.identifier.issn | 15222594 | en_US |
dc.identifier.issn | 07403194 | en_US |
dc.identifier.other | 2-s2.0-85076378137 | en_US |
dc.identifier.other | 10.1002/mrm.28110 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85076378137&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/68468 | - |
dc.description.abstract | © 2019 International Society for Magnetic Resonance in Medicine Purpose: To demonstrate the feasibility of pseudo-continuous arterial-spin–labeled (pCASL) imaging with 3D fast-spin-echo stack-of-spirals on a compact 3T scanner (C3T), to perform trajectory correction for eddy-current–induced deviations in the spiral readout of pCASL imaging, and to assess the correction effect on perfusion-related images with high-performance gradients (80 mT/m, 700T/m/s) of the C3T. Methods: To track eddy-current–induced artifacts with Archimedean spiral readout, the spiral readout in pCASL imaging was performed with 5 different peak gradient slew rate (Smax) values ranging from 70 to 500 T/m/s. The trajectory for each Smax was measured using a dynamic field camera and applied in a density-compensated gridding image reconstruction in addition to the nominal trajectory. The effect of the trajectory correction was assessed with perfusion-weighted (ΔM) images and proton-density–weighted images as well as cerebral blood flow (CBF) maps, obtained from 10 healthy volunteers. Results: Blurring artifact on ΔM images was mitigated by the trajectory correction. CBF values on the left and right calcarine cortices showed no significant difference after correction. Also, the signal-to-noise ratio of ΔM images improved, on average, by 7.6% after correction (P <.001). The greatest improvement of 12.1% on ΔM images was achieved with a spiral readout using Smax of 300~400 T/m/s. Conclusion: Eddy currents can cause spiral trajectory deviation, which leads to deformation of the CBF map even in cases of low value Smax. The trajectory correction for spiral-readout–based pCASL produces more reliable results for perfusion imaging. These results suggest that pCASL is feasible on C3T with high-performance gradients. | en_US |
dc.subject | Medicine | en_US |
dc.title | The effect of spiral trajectory correction on pseudo-continuous arterial spin labeling with high-performance gradients on a compact 3T scanner | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | Magnetic Resonance in Medicine | en_US |
article.volume | 84 | en_US |
article.stream.affiliations | Hanyang University | en_US |
article.stream.affiliations | Mayo Clinic | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.