Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/68294
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Songheng Loem | en_US |
dc.contributor.author | Thoranis Deethayat | en_US |
dc.contributor.author | Attakorn Asanakham | en_US |
dc.contributor.author | Tanongkiat Kiatsiriroat | en_US |
dc.date.accessioned | 2020-04-02T15:24:28Z | - |
dc.date.available | 2020-04-02T15:24:28Z | - |
dc.date.issued | 2020-01-01 | en_US |
dc.identifier.issn | 14321181 | en_US |
dc.identifier.issn | 09477411 | en_US |
dc.identifier.other | 2-s2.0-85080947315 | en_US |
dc.identifier.other | 10.1007/s00231-020-02839-4 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85080947315&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/68294 | - |
dc.description.abstract | © 2020, Springer-Verlag GmbH Germany, part of Springer Nature. In this study, RT-18 HC phase change material (PCM) having a melting point at 18 °C in a form of packed bed was used to reduce the power consumption of a 1 TR inverter air conditioner. A set of spherical balls was packed and integrated with the air conditioner for reducing the air temperature before entering the evaporator coil. The enthalpy method was developed for calculating the PCM temperatures and verified by testing results. The operating parameters such as bed thickness, air mass flow rate, inlet air temperature, operating time and properties of air and PCM during charging and discharging modes were also correlated in dimensionless forms. With the correlations, the charging and the discharging modes for three PCM bed thicknesses: 0.08 m, 0.16 m, and 0.24 m were evaluated, and it could be found that the results from the correlations agreed well with those from the experimental data within ±6% deviation. In addition, the electrical power consumptions of the air conditioner with these integrated PCM beds were 4.96 kWh/d, 4.7 kWh/d and 4.34 kWh/d compared with 5.04 kWh/d of the normal unit or 1.58, 6.80 and 13.84% of electrical energy could be saved, respectively. | en_US |
dc.subject | Chemical Engineering | en_US |
dc.subject | Physics and Astronomy | en_US |
dc.title | Study on phase change material thermal characteristics during air charging/discharging for energy saving of air-conditioner | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | Heat and Mass Transfer/Waerme- und Stoffuebertragung | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.