Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/65634
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Sirinart Sirilert | en_US |
dc.contributor.author | Fuanglada Tongprasert | en_US |
dc.contributor.author | Kasemsri Srisupundit | en_US |
dc.contributor.author | Theera Tongsong | en_US |
dc.contributor.author | Suchaya Luewan | en_US |
dc.date.accessioned | 2019-08-05T04:37:58Z | - |
dc.date.available | 2019-08-05T04:37:58Z | - |
dc.date.issued | 2019-04-01 | en_US |
dc.identifier.issn | 15509613 | en_US |
dc.identifier.issn | 02784297 | en_US |
dc.identifier.other | 2-s2.0-85063638775 | en_US |
dc.identifier.other | 10.1002/jum.14786 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85063638775&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/65634 | - |
dc.description.abstract | © 2018 by the American Institute of Ultrasound in Medicine Objective: This study aims to establish the z score reference ranges of cardiothoracic diameter ratio (CTR) of normal fetuses from 14 to 40 weeks’ gestation. Method: A cross-sectional study was conducted on low-risk singleton pregnancies with healthy fetuses. The CTR was performed using simple 2-dimensional sonography on the typical fetal 4-chamber view. The reference ranges were constructed according to gestational age (GA), biparietal diameter (BPD), and head circumference (HC) as independent variables based on the best-fit models, both mean and standard deviation (SD). Results: A total of 683 fetuses were measured for CTR. The best-fit equations for the mean and SD as a function of GA, BPD, and HC are as follows: (1) CTR = 0.365 + 0.004 × GA in weeks (SD = 0.031 + 0.001 × GA); (2) CTR = 0.373 + 0.014 × BPD in cm (SD = 0.034 + 0.004 × BPD); and (3) CTR = 0.373 + 0.004 × HC in cm (SD = 0.032 + 0.001 × HC). The CTR was slightly increased with advanced GA, BPD, and HC. Conclusion: Complete nomograms with z score reference ranges of CTR were established throughout pregnancy. These nomograms may be useful to detect cardiac abnormalities. | en_US |
dc.subject | Health Professions | en_US |
dc.subject | Medicine | en_US |
dc.title | Z Score Reference Ranges of Fetal Cardiothoracic Diameter Ratio | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | Journal of Ultrasound in Medicine | en_US |
article.volume | 38 | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.