Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/65483
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Wanpen Khongpet | en_US |
dc.contributor.author | Somkid Pencharee | en_US |
dc.contributor.author | Chanida Puangpila | en_US |
dc.contributor.author | Supaporn Kradtap Hartwell | en_US |
dc.contributor.author | Somchai Lapanantnoppakhun | en_US |
dc.contributor.author | Jaroon Jakmunee | en_US |
dc.date.accessioned | 2019-08-05T04:34:02Z | - |
dc.date.available | 2019-08-05T04:34:02Z | - |
dc.date.issued | 2019-06-01 | en_US |
dc.identifier.issn | 0026265X | en_US |
dc.identifier.other | 2-s2.0-85063209759 | en_US |
dc.identifier.other | 10.1016/j.microc.2019.03.040 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85063209759&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/65483 | - |
dc.description.abstract | © 2019 A simple and compact microfluidic hydrodynamic sequential injection system with a colorimetric detection has been developed for the consecutive determination of phosphate and ammonium in water samples based on molybdenum blue and Berthelot methods. A light-emitting diode as a light source and light dependent resistor light sensor were mounted onto the acrylic microfluidic unit for on-line sample and reagents mixing. This portable and miniaturized analytical system was operated automatically by computerized control switching of solenoid valves. Under the optimum operational condition, a linear calibration graph of phosphate and ammonium (as phosphorus, P, and nitrogen, N) in the range of 0.2–3.0 mg P L −1 and 0.3–4.0 mg N L −1 , were achieved with a sample-throughput of 12 h −1 . Limit of detection values for phosphate and ammonium were 0.18 and 0.27 mg L −1 , respectively. The developed system provides a good precision with relative standard deviations of 2.9 and 4.1% for 11 replicated injections of 1 mg P L −1 and 2 mg N L −1 , respectively. Percent recoveries of the analysis of phosphate and ammonium were obtained in the range of 93.5–109.4 and 92.4–107.0, respectively. The developed system offers a compact, durable, cost-effective instrument, with low reagents consumption, that is suitable for monitoring water quality. | en_US |
dc.subject | Chemistry | en_US |
dc.title | A compact hydrodynamic sequential injection system for consecutive on-line determination of phosphate and ammonium | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | Microchemical Journal | en_US |
article.volume | 147 | en_US |
article.stream.affiliations | Ubon Rajathanee University | en_US |
article.stream.affiliations | Xavier University | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.