Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/65413
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPipoon Boonpengen_US
dc.contributor.authorPonlayuth Sooksamitien_US
dc.contributor.authorSomchai Lapanantnoppakhunen_US
dc.contributor.authorJaroon Jakmuneeen_US
dc.date.accessioned2019-08-05T04:33:04Z-
dc.date.available2019-08-05T04:33:04Z-
dc.date.issued2019-01-01en_US
dc.identifier.issn01252526en_US
dc.identifier.other2-s2.0-85068000966en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85068000966&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/65413-
dc.description.abstract© 2019, Chiang Mai University. All rights reserved. Anodic stripping voltammetric (ASV) method using a screen-printed carbon electrode (SPCE) modified with gold nanoparticles and with anion exchange column preconcentration/ separation was developed for determination of trace inorganic arsenic. The gold nanoparticles were in-situ electro-deposited on the SPCE while the As(III) was preconcentrated on the electrode at -500 mV versus Ag/AgCl reference electrode during a deposition step. Then, differential pulse waveform was scanned from 0 to +800 mV and a voltammogram was recorded during a stripping step. Under the optimum condition of 0.10 M HCl as an electrolyte solution, -500 mV deposition potential, 60 s deposition time, and 33.33 mV/s scan rate, a linear calibration graph in the range of 30 - 150 µg/L with a calibration slope of 0.110 µA L/µg (R2 = 0.998) was obtained. Limit of detection of 8.9 µg/L was achieved and with good precision, i.e., relative standard deviation is in the range of 0.7 - 1.3 %. In addition, anion exchange column was applied for preconcentration and separation of arsenic species which help to improve sensitivity and selectivity of the method. As(V) was retained in the column while As(III) and other interfering cations were passed through. The As(V) was then desorbed by using 0.10 M HCl and reduced to As(III) by L-cysteine before ASV determination. The proposed method was applied for determination of inorganic arsenic in soil extracted samples with satisfactory results.en_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectChemistryen_US
dc.subjectMaterials Scienceen_US
dc.subjectMathematicsen_US
dc.subjectPhysics and Astronomyen_US
dc.titleDetermination of inorganic arsenic by anodic stripping voltammetry with gold nanoparticles modified screen-printed carbon electrode and anion exchange column preconcentrationen_US
dc.typeJournalen_US
article.title.sourcetitleChiang Mai Journal of Scienceen_US
article.volume46en_US
article.stream.affiliationsChiang Mai Universityen_US
article.stream.affiliationsThe Office of Primary Industries and Mines Region 3en_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.