Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/61812
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Suchaya Silvilairat | en_US |
dc.contributor.author | Yupada Pongprot | en_US |
dc.contributor.author | Rekwan Sittiwangkul | en_US |
dc.contributor.author | Charlie Phornphutkul | en_US |
dc.date.accessioned | 2018-09-11T08:59:34Z | - |
dc.date.available | 2018-09-11T08:59:34Z | - |
dc.date.issued | 2006-10-11 | en_US |
dc.identifier.issn | 01252208 | en_US |
dc.identifier.issn | 01252208 | en_US |
dc.identifier.other | 2-s2.0-33749452699 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33749452699&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/61812 | - |
dc.description.abstract | Objective: To determine factors influencing immediate and medium-term results of Pulmonary Balloon Valvuloplasty (PBV) for pulmonary valve stenosis. Material and Method: Between 1995 and 2001, the authors carried out PBV in 25 consecutive patients. Two treatment outcomes including immediate and medium-term results were analyzed. The immediate results were classified into two groups based on the pulmonary systolic pressure gradient (PG) immediately after dilation: group I with a PG ≤ 35 mmHg and group II with a PG > 35 mmHg. At medium-term follow-up of 6 to 60 months, echocardiographic evaluations were analyzed and divided into two groups: group A with a PG ≤ 25 mmHg and group B with a PG > 25 mmHg. Demographic characteristics and hemodynamic parameters of immediate and medium-term results were compared and analyzed. Results: Immediately after PBV, the right ventricular systolic pressure (RVSP) decreased from 115.3 □ 37.6 mmHg to 67.0 □ 28.5 mmHg (p < 0.001). The pulmonary systolic pressure gradient decreased from 90.4 □ 37.9 mmHg to 39.3 □ 25.6 mmHg (p < 0.001). Nine of the 25 patients (group II; 36%), with incomplete immediate relief of the obstruction, had more symptoms, a higher baseline PG, higher right atrial pressure, higher RVSP, and a higher systolic pressure ratio. Six of the 25 patients (group B; 24%), with suboptimal medium-term results, had a higher right ventricular voltage on the electrocardiogram, higher pre-dilation PG, and higher RVSP. Conclusion: Successful medium-term outcomes following pulmonary balloon valvuloplasty were achieved in 76% of the patients, with a greater success rate (91%) in patients with a lower right ventricular voltage electrocardiogram (R wave amplitude in V 1) ≤ 21 mm, a prevalvuloplasty systolic gradient ≤ 90 mmHg, and right ventricular systolic pressure ≤ 125 mmHg. | en_US |
dc.subject | Medicine | en_US |
dc.title | Factors determining immediate and medium-term results after pulmonary balloon valvuloplasty | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | Journal of the Medical Association of Thailand | en_US |
article.volume | 89 | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
article.stream.affiliations | Department of Pediatrics | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.