Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/61615
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSangsom Prapayasatoken_US
dc.contributor.authorA. Janhomen_US
dc.contributor.authorK. Verochanaen_US
dc.contributor.authorS. Pramojaneeen_US
dc.date.accessioned2018-09-11T08:56:03Z-
dc.date.available2018-09-11T08:56:03Z-
dc.date.issued2006-07-01en_US
dc.identifier.issn0250832Xen_US
dc.identifier.other2-s2.0-33746088452en_US
dc.identifier.other10.1259/dmfr/32165678en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33746088452&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/61615-
dc.description.abstractObjectives: To evaluate the diagnostic accuracy of proximal caries detection from digitized film images captured by a digital camera at different resolution settings. Methods: Twenty-five periapical radiographs of 50 premolar and 25 molar teeth were photographed using a digital camera, Sony Cyber-shot, DSC-S75 at three different resolution settings: 640 X 480,1280 X 960 and 1600 X 1200. Seventy-five digital images were transferred to a computer, saved and opened using ACDSee software. In addition, a PowerPoint slide was made from each digital image. Five observers scored three groups of images (the films, the displayed 1:1 digital images on the ACDSee software, and the PowerPoint slides) for the existence of proximal caries using a 5-point confidence scale, and the depth of caries on a 4-point scale. Ground sections of the teeth were used as the gold standard. Az values under the receiver operating characteristic (ROC) curve of each group of images and at different resolutions were compared using the Friedman and Wilcoxon signed rank tests. Mean different values between the lesions' depth interpreted by the observers and that of the gold standard were analysed. Results: Films showed the highest Az values. Only the 1280 X 960 images on the ACDSee software showed no significant difference of the A2 value from the films (P = 0.28). The digital images from three resolution settings on the PowerPoint slides showed no significant differences, either among each other or between them and the films. For caries depth, the 1280 X 960 images showed lower values of mean difference in enamel lesions compared with the other two resolution groups. Conclusions: This study showed that in order to digitize conventional films, it was not necessary to use the highest camera resolution setting to achieve high diagnostic accuracy for proximal caries detection. The 1280 X 960 resolution setting of the digital camera demonstrated comparable diagnostic accuracy with film and was adequate for digitizing radiographs for caries detection. © 2006 The British Institute of Radiology.en_US
dc.subjectDentistryen_US
dc.subjectHealth Professionsen_US
dc.subjectMedicineen_US
dc.titleDigital camera resolution and proximal caries detectionen_US
dc.typeJournalen_US
article.title.sourcetitleDentomaxillofacial Radiologyen_US
article.volume35en_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.