Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/61530
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Gillian M. Greenway | en_US |
dc.contributor.author | Tapparath Leelasattarathkul | en_US |
dc.contributor.author | Saisunee Liawruangrath | en_US |
dc.contributor.author | R. Alan Wheatley | en_US |
dc.contributor.author | Napaporn Youngvises | en_US |
dc.date.accessioned | 2018-09-11T08:54:40Z | - |
dc.date.available | 2018-09-11T08:54:40Z | - |
dc.date.issued | 2006-04-04 | en_US |
dc.identifier.issn | 00032654 | en_US |
dc.identifier.other | 2-s2.0-33645366735 | en_US |
dc.identifier.other | 10.1039/b513735g | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33645366735&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/61530 | - |
dc.description.abstract | A novel ultrasonic flow injection chemiluminescence (FI-CL) manifold for determining hydrogen peroxide (H2O2) has been designed and evaluated. Chemiluminescence obtained from the luminol-H2O2-cobalt(ii) reaction was enhanced by applying 120 W of ultrasound for a period of 4 s to the reaction coil in the FI-CL system and this enhancement was verified by comparison with an identical manifold without ultrasound. The system was developed for determining ultra-trace levels of H2O2and a calibration curve was obtained with a linear portion over the range of 10-200 nmol L-1H2O2(correlation coefficient 0.9945). The detection limit (3σ) and the quantification limit (LOQ) were found to be 1 × 10-9and 3.3 × 10-9mol L-1respectively and the relative standard deviation was 1.37% for 2 × 10-7mol L-1H2O2(n = 10). The method was applied to the determination of trace amounts of H2O2in purified water and natural water samples without any special pre-treatments. © The Royal Society of Chemistry 2006. | en_US |
dc.subject | Biochemistry, Genetics and Molecular Biology | en_US |
dc.subject | Chemistry | en_US |
dc.subject | Environmental Science | en_US |
dc.title | Ultrasound-enhanced flow injection chemiluminescence for determination of hydrogen peroxide | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | Analyst | en_US |
article.volume | 131 | en_US |
article.stream.affiliations | University of Hull | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
article.stream.affiliations | Thammasat University | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.