Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/60952
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKritsana Jitmaneeen_US
dc.contributor.authorNorio Teshimaen_US
dc.contributor.authorTadao Sakaien_US
dc.contributor.authorKate Grudpanen_US
dc.date.accessioned2018-09-10T04:01:54Z-
dc.date.available2018-09-10T04:01:54Z-
dc.date.issued2007-09-15en_US
dc.identifier.issn00399140en_US
dc.identifier.other2-s2.0-34547745904en_US
dc.identifier.other10.1016/j.talanta.2007.03.054en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=34547745904&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/60952-
dc.description.abstractA flow injection system with anion exchange resin minicolumns was coupled with dynamic reaction cell (DRC™) ICP-MS for the determination and speciation of selenite and selenate at sub μg L-1levels. The charged selenate and uncharged selenite were separated on the first resin column in which only selenate was retained. The unretained selenite was then deprotonated with alkaline solution, and the resulting anionic selenite species was collected on the second column serially connected downstream. By setting a sample loop, total selenium can be determined together with selenite and selenate. The selenium species was eluted by nitric acid and carried to DRC™ ICP-MS for their detection. Using ammonia as reaction gas, the detection of78Se was improved. The enrichment factor was 20 for 10 mL of sample. The standard deviations (n = 5) of peak heights were 4.9%, 4.1%, and 7.0% for a 5.0 × 10-2μg L-1selenite and selenate, and total Se, respectively. The calibration graphs were linear from 2.0 × 10-2to 1.0 μg L-1selenite and selenate. And, the linearity for total selenium was good in the range of 10.0 × 10-2to 1.0 μg L-1. The proposed method has been demonstrated for the application to natural and bottled drinking water samples. © 2007 Elsevier B.V. All rights reserved.en_US
dc.subjectChemistryen_US
dc.titleDRC™ ICP-MS coupled with automated flow injection system with anion exchange minicolumns for determination of selenium compounds in water samplesen_US
dc.typeJournalen_US
article.title.sourcetitleTalantaen_US
article.volume73en_US
article.stream.affiliationsAichi Institute of Technologyen_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.