Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/60596
Full metadata record
DC FieldValueLanguage
dc.contributor.authorHe Wangen_US
dc.contributor.authorKathy J. Simpsonen_US
dc.contributor.authorSamatchai Chamnongkichen_US
dc.contributor.authorTracy Kinseyen_US
dc.contributor.authorOrmonde M. Mahoneyen_US
dc.date.accessioned2018-09-10T03:45:52Z-
dc.date.available2018-09-10T03:45:52Z-
dc.date.issued2008-09-05en_US
dc.identifier.issn14765918en_US
dc.identifier.other2-s2.0-50649115933en_US
dc.identifier.other10.1186/1476-5918-7-12en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=50649115933&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/60596-
dc.description.abstractBackground. Compared to the design of a traditional multi-radius (MR) total knee arthroplasty (TKA), the single-radius (SR) implant investigated has a fixed flexion/extension center of rotation. The biomechanical effectiveness of an SR for functional daily activities, i.e., sit-to-stand, is not well understood. The purpose of the study was to compare the biomechanics underlying functional performance of the sit-to-stand (STS) movement between the limbs containing an MR and an SR TKA of bilateral TKA participants. Methods. Sagittal plane kinematics and kinetics, and EMG data for selected knee flexor and extensor muscles were analyzed for eight bilateral TKA patients, each with an SR and an MR TKA implant. Results. Compared to the MR limb, the SR limb demonstrated greater peak antero-posterior (AP) ground reaction force, higher AP ground reaction impulse, less vastus lateralis and semitendinosus EMG during the forward-thrust phase of the STS movement. No significant difference of knee extensor moment was found between the two knees. Conclusion. Some GRF and EMG differences were evident between the MR and SR limbs during STS movement. Compensatory adaptations may be used to perform the STS. © 2008 Wang et al; licensee BioMed Central Ltd.en_US
dc.subjectMedicineen_US
dc.titleBiomechanical influence of TKA designs with varying radii on bilateral TKA patients during sit-to-standen_US
dc.typeJournalen_US
article.title.sourcetitleDynamic Medicineen_US
article.volume7en_US
article.stream.affiliationsBall State Universityen_US
article.stream.affiliationsThe University of Georgiaen_US
article.stream.affiliationsChiang Mai Universityen_US
article.stream.affiliationsAthens Orthopedic Clinicen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.