Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/60569
Full metadata record
DC FieldValueLanguage
dc.contributor.authorEduard Gershkevitshen_US
dc.contributor.authorRainer Schmidten_US
dc.contributor.authorGraciela Velezen_US
dc.contributor.authorDan Milleren_US
dc.contributor.authorErhardt Korfen_US
dc.contributor.authorFernando Yipen_US
dc.contributor.authorSomsak Wanwilairaten_US
dc.contributor.authorStanislav Vatnitskyen_US
dc.date.accessioned2018-09-10T03:45:33Z-
dc.date.available2018-09-10T03:45:33Z-
dc.date.issued2008-12-01en_US
dc.identifier.issn01678140en_US
dc.identifier.other2-s2.0-56949088380en_US
dc.identifier.other10.1016/j.radonc.2008.07.007en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=56949088380&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/60569-
dc.description.abstractBackground and purpose: The methodology developed by IAEA for dosimetric quality control of treatment planning systems has been tested in different hospitals through a pilot study. The aim was to verify the methodology and observe the range of deviations between planned and delivered doses in 3D conformal radiotherapy in situations close to a clinical setting. Material and methods: The methodology was based on an anthropomorphic phantom representing the human thorax, and simulates the whole chain of external beam radiotherapy treatment planning activities. The phantom was scanned using computed tomography and eight test cases were planned on treatment planning systems which imitate different irradiation geometries found in conformal radiotherapy. The doses were measured with ion chambers, and the deviation between measured and treatment planning system calculated doses was reported. This methodology, which employs the same phantom and the same set of test cases, was tested in 17 different hospitals which were using 14 different algorithms/inhomogeneity correction methods implemented in different treatment planning systems. Results: A total of 53 clinical test case datasets for different energies and calculation algorithms were produced. Most of the systems with advanced algorithms complied with predefined agreement criteria. Dose differences more than 20% were discovered for some of the simple algorithms and high energy X-ray beams. The number of deviations outside agreement criteria increases with the beam energy and decreases with advancement of the treatment planning system calculation algorithm. Conclusions: Large deviations exist in some simple dose calculation algorithms, therefore more advanced algorithms would be preferable and therefore should be implemented in clinical practice. The test cases that could be performed in reasonable time would help the users to appreciate the possibilities of their system and understand its limitations. © 2008 Elsevier Ireland Ltd. All rights reserved.en_US
dc.subjectMedicineen_US
dc.titleDosimetric verification of radiotherapy treatment planning systems: Results of IAEA pilot studyen_US
dc.typeJournalen_US
article.title.sourcetitleRadiotherapy and Oncologyen_US
article.volume89en_US
article.stream.affiliationsNorth Estonia Regional Hospitalen_US
article.stream.affiliationsUniversitatsklinikum Hamburg-Eppendorf und Medizinische Fakultaten_US
article.stream.affiliationsCABINen_US
article.stream.affiliationsLoma Linda University Medical Centeren_US
article.stream.affiliationsSouthern Cross Hospitalen_US
article.stream.affiliationsInstituto Nacional de Oncologia y Radiobiologia, Havana, cuen_US
article.stream.affiliationsChiang Mai Universityen_US
article.stream.affiliationsInternational Atomic Energy Agency, Viennaen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.