Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/57992
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPathawee Khongkhunthianen_US
dc.contributor.authorKanoknual Jomjunyongen_US
dc.contributor.authorPeter A. Reicharten_US
dc.date.accessioned2018-09-05T03:55:52Z-
dc.date.available2018-09-05T03:55:52Z-
dc.date.issued2017-01-01en_US
dc.identifier.issn16851994en_US
dc.identifier.other2-s2.0-85014439596en_US
dc.identifier.other10.12982/cmujns.2017.0005en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85014439596&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/57992-
dc.description.abstractThis study evaluated the accuracy of cone beam computed tomography (CBCT) measurements using post-surgical, implant placement, CBCT images by measuring the length and width of implants on CBCT images and comparing these measurements to the actual sizes of the implants, as well as investigated critical anatomical structure injuries after using CBCT for planning. Ninety-six post-operative CBCT scans of 171 dental implants, placed between October 2012 and March 2015, were included in the study. Each implant was measured on the CBCT images for both diameter and length, using the measuring tool in the CBCT software. The measured values were compared with the actual implant diameters and lengths and calculated as a percentage of error. The mean percentage of error was 2.26%. There were no significant differences in percentage of error between implant size, implant diameters, implant positions, upper jaw, lower jaw, anterior area, or posterior area (p>0.05). Anatomical structure injuries were not found post-operatively. The accuracy of CBCT used for measurement in this study was 97.74%, and comparable to that reported for other commercial CBCT machines. The use of CBCT for implant planning can avoid anatomical structure injuries.en_US
dc.subjectMultidisciplinaryen_US
dc.titleAccuracy of cone beam computed tomography for dental implant treatment planningen_US
dc.typeJournalen_US
article.title.sourcetitleChiang Mai University Journal of Natural Sciencesen_US
article.volume16en_US
article.stream.affiliationsChiang Mai Universityen_US
article.stream.affiliationsCharité – Universitätsmedizin Berlinen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.