Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/57817
Full metadata record
DC FieldValueLanguage
dc.contributor.authorJagannathan Madhanagopalen_US
dc.contributor.authorOm Prakash Singhen_US
dc.contributor.authorVikram Mohanen_US
dc.contributor.authorKathiresan V. Sathasivamen_US
dc.contributor.authorAbdul Hafidz Omaren_US
dc.contributor.authorMohammed Rafiq Abdul Kadiren_US
dc.date.accessioned2018-09-05T03:50:16Z-
dc.date.available2018-09-05T03:50:16Z-
dc.date.issued2017-01-01en_US
dc.identifier.issn15523918en_US
dc.identifier.issn01632787en_US
dc.identifier.other2-s2.0-85046024020en_US
dc.identifier.other10.1177/0163278717727568en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85046024020&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/57817-
dc.description.abstract© 2017, The Author(s) 2017. An accurate measurement of intrinsic hand muscle strength (IHMS) is required by clinicians for effective clinical decision-making, diagnosis of certain diseases, and evaluation of the outcome of treatment. In practice, the clinicians use Intrins-o-meter and Rotterdam Intrinsic Hand Myometer for IHMS measurement. These are quite bulky, expensive, and possess poor interobserver reliability (37–52%) and sensitivity. The purpose of this study was to develop an alternative lightweight, accurate, cost-effective force measurement device with a simple electronic circuit and test its suitability for IHMS measurement. The device was constructed with ketjenblack/deproteinized natural rubber sensor, 1-MΩ potential divider, and Arduino Uno through the custom-written software. Then, the device was calibrated and tested for accuracy and repeatability within the force range of finger muscles (100 N). The 95% limit of agreement in accuracy from −1.95 N to 2.06 N for 10 to 100 N applied load and repeatability coefficient of ±1.91 N or 6.2% was achieved. Furthermore, the expenditure for the device construction was around US$ 53. For a practical demonstration, the device was tested among 16 participants for isometric strength measurement of the ulnar abductor and dorsal interossei. The results revealed that the performance of the device was suitable for IHMS measurement.en_US
dc.subjectMedicineen_US
dc.titleNew Device for Intrinsic Hand Muscle Strength Measurement: An Alternative to Strain Gauge Handheld Dynamometeren_US
dc.typeJournalen_US
article.title.sourcetitleEvaluation and the Health Professionsen_US
article.stream.affiliationsUniversiti Teknologi Malaysiaen_US
article.stream.affiliationsChiang Mai Universityen_US
article.stream.affiliationsUniversiti Teknologi MARAen_US
article.stream.affiliationsAsian Institute of Medicine, Science & Technologyen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.