Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/57805
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPasuk Mahakkanukrauhen_US
dc.contributor.authorApichat Sinthubuaen_US
dc.contributor.authorSitthiporn Ruengditen_US
dc.contributor.authorSrijit Dasen_US
dc.date.accessioned2018-09-05T03:50:02Z-
dc.date.available2018-09-05T03:50:02Z-
dc.date.issued2017-01-01en_US
dc.identifier.issn13412051en_US
dc.identifier.other2-s2.0-85018344045en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85018344045&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/57805-
dc.description.abstract© 2017 Japan Health Sciences University & Japan International Cultural Exchange Foundation. Background and Aims: Sternum is a flat bone which is divided into different parts i.e. manubrium, body and xiphoid process. The xiphoid process is a thin plate of cartilage to which there is no rib attachment. The main aim of the present study was to observe the abnormal foramens in the xiphoid process of the sternum. Design: An osteological study on the sternum to observe the presence of any foramina in the xiphoid process. Methods: Hundred human sterni were collected from the bone repository in Forensic Osteology Research Centre, Chiang Mai University, Thailand. The sternum was studied for any abnormal foramina in the xiphoid process. Appropriate measurements of the foramina were taken. Results: Out of 100 bone specimens of sternum, only 4 specimens exhibited anomalous foramina in the xiphoid process. There was single foramen in 3 specimens. These foramina measured 3.8 mm, 4.11 mm and 10.8 mm as maximum transverse diameter, respectively. The foramina measured 4.61 mm, 4.40 mm 16.89 mm as maximum vertical diameter, respectively. The specimen which exhibited double foramina in the xiphoid process had the upper and lower foramina measuring 4.40 mm and 4.43 mm as the transverse diameter whereas both foramina measured 5.34 mm and 5.43 mm in vertical diameter, respectively. Conclusion: Presence of abnormal foramen in the sternum may mislead radiographic investigations, result in inadvertent injuries during cardiopulmonary resuscitation and sternal biopsies. Anatomical knowledge of abnormal foramina in the xiphoid process may be important for both academic and clinical purpose.en_US
dc.subjectMedicineen_US
dc.titleAnomalous foramina in the xiphoid process of the sternum: Anatomical considerations and clinical significanceen_US
dc.typeJournalen_US
article.title.sourcetitleInternational Medical Journalen_US
article.volume24en_US
article.stream.affiliationsChiang Mai Universityen_US
article.stream.affiliationsUniversiti Kebangsaan Malaysiaen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.