Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/57675
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Etienne M. Schönbach | en_US |
dc.contributor.author | Voraporn Chaikitmongkol | en_US |
dc.contributor.author | Rachel Annam | en_US |
dc.contributor.author | Emma C. McDonnell | en_US |
dc.contributor.author | Yulia Wolfson | en_US |
dc.contributor.author | Emily Fletcher | en_US |
dc.contributor.author | Hendrik P.N. Scholl | en_US |
dc.date.accessioned | 2018-09-05T03:47:53Z | - |
dc.date.available | 2018-09-05T03:47:53Z | - |
dc.date.issued | 2017-07-01 | en_US |
dc.identifier.issn | 14230259 | en_US |
dc.identifier.issn | 00303747 | en_US |
dc.identifier.other | 2-s2.0-85021086820 | en_US |
dc.identifier.other | 10.1159/000475996 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85021086820&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/57675 | - |
dc.description.abstract | © 2017 S. Karger AG, Basel. Purpose: We present the multifocal electroretinogram (mfERG) with a 7-hexagon array as an objective test of macular function that can be recorded in 14 s. We provide normal values and investigate its reproducibility and validity. Methods: Healthy participants underwent mfERG testing according to International Society for Clinical Electrophysiology of Vision (ISCEV) standards using the Espion Profile/D310 multifocal ERG system (Diagnosys, LLC, Lowell, MA, USA). One standard recording of a 61-hexagon array and 2 repeated recordings of a custom 7-hexagon array were obtained. Results: A total of 13 subjects (mean age 46.9 years) were included. The median response densities were 12.5 nV/deg2 in the center and 5.2 nV/deg2 in the periphery. Intereye correlations were strong in both the center (ρCenter = 0.821; p < 0.0001) and the periphery (ρPeriphery = 0.862; p < 0.0001). Intraeye correlations were even stronger: ρCenter = 0.904 with p < 0.0001 and ρPeriphery = 0.955 with p < 0.0001. Bland-Altman plots demonstrated an acceptable retest mean difference in both the center and periphery, and narrow limits of agreement. We found strong correlations of the center (ρCenter = 0.826; p < 0.0001) and periphery (ρPeriphery = 0.848; p < 0.0001), with recordings obtained by the 61-hexagon method. Conclusions: The 7-hexagon mfERG provides reproducible results in agreement with results obtained according to the ISCEV standard. | en_US |
dc.subject | Medicine | en_US |
dc.subject | Neuroscience | en_US |
dc.title | 7-Hexagon Multifocal Electroretinography for an Objective Functional Assessment of the Macula in 14 Seconds | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | Ophthalmic Research | en_US |
article.volume | 58 | en_US |
article.stream.affiliations | The Wilmer Eye Institute at Johns Hopkins | en_US |
article.stream.affiliations | Griffin Hospital Derby | en_US |
article.stream.affiliations | UT Southwestern Medical School | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
article.stream.affiliations | Cheltenham General Hospital | en_US |
article.stream.affiliations | Universitatsspital Basel | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.