Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/57570
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Uten Yarach | en_US |
dc.contributor.author | Myung Ho In | en_US |
dc.contributor.author | Itthi Chatnuntawech | en_US |
dc.contributor.author | Berkin Bilgic | en_US |
dc.contributor.author | Frank Godenschweger | en_US |
dc.contributor.author | Hendrik Mattern | en_US |
dc.contributor.author | Alessandro Sciarra | en_US |
dc.contributor.author | Oliver Speck | en_US |
dc.date.accessioned | 2018-09-05T03:46:07Z | - |
dc.date.available | 2018-09-05T03:46:07Z | - |
dc.date.issued | 2017-12-01 | en_US |
dc.identifier.issn | 15222594 | en_US |
dc.identifier.issn | 07403194 | en_US |
dc.identifier.other | 2-s2.0-85012908532 | en_US |
dc.identifier.other | 10.1002/mrm.26633 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85012908532&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/57570 | - |
dc.description.abstract | © 2017 International Society for Magnetic Resonance in Medicine Purpose: To describe a model-based reconstruction strategy for single-shot echo planar imaging (EPI) that intrinsically accounts for k-space nonuniformity, Nyquist ghosting, and geometric distortions during rather than before or after image reconstruction. Methods: Ramp sampling and inhomogeneous B0 field-induced distortion cause the EPI samples to lie on a non-Cartesian grid, thus requiring the nonuniform fast Fourier transform. Additionally, a 2D Nyquist ghost phase correction without the need for extra navigator acquisition is included in the proposed reconstruction. Coil compression is also incorporated to reduce the computational load. The proposed method is applied to phantom and human brain MRI data. Results: The results demonstrate that Nyquist ghosting and geometric distortions are reduced by the proposed reconstruction. The proposed 2D phase correction is superior to a conventional 1D correction. The reductions of both artifacts lead to improved temporal signal-to-noise ratio (tSNR). The virtual coil results suggest that the processing time can be reduced by up to 75%, with a mean tSNR loss of only 3.2% when using 8-virtual instead of 32-physical coils for twofold undersampled data. Conclusion: The proposed reconstruction improves the quality (ghosting, geometry, and tSNR) of EPI without requiring calibration data for Nyquist ghost correction. Magn Reson Med 78:2250–2264, 2017. © 2017 International Society for Magnetic Resonance in Medicine. | en_US |
dc.subject | Medicine | en_US |
dc.title | Model-based iterative reconstruction for single-shot EPI at 7T | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | Magnetic Resonance in Medicine | en_US |
article.volume | 78 | en_US |
article.stream.affiliations | Otto von Guericke University of Magdeburg | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
article.stream.affiliations | Mayo Clinic | en_US |
article.stream.affiliations | Thailand National Science and Technology Development Agency | en_US |
article.stream.affiliations | Harvard Medical School | en_US |
article.stream.affiliations | Massachusetts General Hospital | en_US |
article.stream.affiliations | Leibniz Institute for Neurobiology | en_US |
article.stream.affiliations | Deutsches Zentrum fur Neurodegenerative Erkrankungen e.V. | en_US |
article.stream.affiliations | Center for Behavioral Brain Sciences | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.