Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/57561
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPatchareewan Khadsirien_US
dc.contributor.authorEkkasit Tharavichitkulen_US
dc.contributor.authorSuwit Saekhoen_US
dc.contributor.authorNisa Chawapunen_US
dc.date.accessioned2018-09-05T03:45:51Z-
dc.date.available2018-09-05T03:45:51Z-
dc.date.issued2017-12-01en_US
dc.identifier.issn14671131en_US
dc.identifier.issn14603969en_US
dc.identifier.other2-s2.0-84986552466en_US
dc.identifier.other10.1017/S1460396916000339en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84986552466&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/57561-
dc.description.abstract© Cambridge University Press 2016. Purpose To develop a software program to convert physical dose distribution into biological effective dose (BED). Methods The MATLAB-based BED distribution software program was designed to import the radiotherapy treatment plan from the computer treatment planning system and to convert the physical dose distribution into the BED distribution. The BED calculation was based on the linear-quadratic-linear model (LQ-L model). Besides radiobiological parameters, other specific data could be fed in through the panel. The accuracy of the program was verified by comparing the BED distribution with manual calculation. Results This software program was able to import the radiotherapy treatment plans and pull out pixel-wised physical dose for BED calculation, and display the isoBED lines on the computed tomographic (CT) image. The verification of BED dose distribution was performed in both phantom and clinical cases. It revealed that there were no differences between the program and manual BED calculations. Conclusion It is feasible and practical to use this in-house BED distribution software program in clinical practices and research work. However, it should be used with caution as the validity of the program depends on the accuracy of the published biological parameters.en_US
dc.subjectMedicineen_US
dc.titleDevelopment of 3D biological effective dose distribution software programen_US
dc.typeJournalen_US
article.title.sourcetitleJournal of Radiotherapy in Practiceen_US
article.volume16en_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.