Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/55178
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAmnat Ruangchaiwaten_US
dc.contributor.authorNarabhats Rannuragsen_US
dc.contributor.authorSukon Phanichphanten_US
dc.contributor.authorBoonsom Liawruangrathen_US
dc.contributor.authorSaisunee Liawruangrathen_US
dc.date.accessioned2018-09-05T02:52:47Z-
dc.date.available2018-09-05T02:52:47Z-
dc.date.issued2016-07-01en_US
dc.identifier.issn01252526en_US
dc.identifier.other2-s2.0-84988956639en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84988956639&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/55178-
dc.description.abstract© 2016, Chiang Mai University. All rights reserved. A very simple laboratory made prototype piezoelectric transducer (PZT) or sensor is described using inexpensive materials and equipment easily available in Chiang Mai and in the laboratory. Initially, experiments are carried out using a single cell device constructed in this laboratory afterwards a double-cell device is modified from the prototype device for measuring gaseous/vapour contaminants in air. The PZT detectors were tested for detection of SO2 on the basis of the best known SO2 detection using triethanolamine as coating material. It was found that the dual-cell device was more sensitive to SO2 (48 Hz ppm) than the single-cell one (6 Hz/ppm). Optimal conditions for the PZT detector were also investigated. The AT-cut quartz crystals with circular shape having thin film gold electrodes on both sides were employed. It was shown that the 10 MHz crytal coated with triethanolamine was more sentitive than the 6 MHz quartz crystal and hence the 10 MHz quartz crystal was selected as optimum. Selectivity of the PZT detector can be achieved by changing the coating materials. Under suitable conditions, choice of appropriate coating materials could be achieved for a number gaseous/vapour samples. The proposed PZT sensors using selective coatings were successfully applied for detection of SO2 and methanol with satisfactory results.en_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectChemistryen_US
dc.subjectMaterials Scienceen_US
dc.subjectMathematicsen_US
dc.subjectPhysics and Astronomyen_US
dc.titleSimple laboratory-made piezoelectric sensors for detection of selected gaseous and/or vapor sampleen_US
dc.typeJournalen_US
article.title.sourcetitleChiang Mai Journal of Scienceen_US
article.volume43en_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.