Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/53791
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLeonard H. Josephen_US
dc.contributor.authorRizuana I. Hussainen_US
dc.contributor.authorUbon Pirunsanen_US
dc.contributor.authorAmaramalar S. Naickeren_US
dc.contributor.authorOhnmar Htween_US
dc.contributor.authorAatit Paungmalien_US
dc.date.accessioned2018-09-04T09:58:13Z-
dc.date.available2018-09-04T09:58:13Z-
dc.date.issued2014-01-01en_US
dc.identifier.issn1017995Xen_US
dc.identifier.other2-s2.0-84899649782en_US
dc.identifier.other10.3944/AOTT.2014.3184en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84899649782&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/53791-
dc.description.abstractObjective: The aim of this study was to investigate the intra-and inter-rater reliability of ultrasonography (US) to measure anterior translation of the humeral head (ATHH) among healthy subjects and patients with sacroiliac joint dysfunction. Methods: The study included a total of 22 shoulder joints from 11 subjects. Six subjects were healthy and 5 had sacroiliac joint dysfunction. Anterior translation of the humeral head was measured twice using US by two different investigators. Intraclass correlation coefficient (ICC3,1), standard error of measurements (SEMs), coefficient of variations (CVs) and Bland-Altman plot were used as analytical tests to investigate intra-and inter-rater reliability, amount of error and agreeability of the measurements between investigators. Results: Intraclass correlation coefficient was 0.94, showing a high level of intra-rater reliability of the first investigator with SEMs (0.01 cm) and CV (5.1%) in measuring ATHH. Intra-rater reliability of the second investigator was 0.84 with SEMs (0.03 cms) and CV (9.6%), indicating a high level of reliability. Inter-rater reliability was high, with an ICC value of 0.92 with SEMs (0.02 cms) and CV (5.9%). Conclusion: The use of US as a measurement of ATHH has good levels of intra-and inter-rater reliability in clinical practice. © 2014 Turkish Association of Orthopaedics and Traumatology.en_US
dc.subjectMedicineen_US
dc.titleClinical evaluation of the anterior translation of glenohumeral joint using ultrasonography: An intra-and inter-rater reliability studyen_US
dc.typeJournalen_US
article.title.sourcetitleActa Orthopaedica et Traumatologica Turcicaen_US
article.volume48en_US
article.stream.affiliationsChiang Mai Universityen_US
article.stream.affiliationsUniversiti Kebangsaan Malaysiaen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.