dc.description.abstract | © 2014 The Authors. Published by Elsevier Ltd. In this study, simulation and experiment studies of a 10 kW solar H2O-LiBr absorption heat transformer (AHT) integrating with a two-stage vapor compression heat pump (VCHP) were carried out. The whole system was named as compression/absorption heat transformer (CAHT). The VCHP was used to recover rejected heat at the AHT condenser which was transferred back to the AHT evaporator at a higher temperature. The AHT unit took solar heat from a set of flat-plate solar collectors in parallel connection. R-134a and R-123 were refrigerants in the VCHP cycle. From the simulation, the total cycle coefficient (COP) of the solar-CAHT was 0.71 compared with 0.49 of the normal solar-AHT. From the experiment, the total cycle COPs of the solar-CAHT and the solar-AHT were 0.62 and 0.39, respectively. The experimental results were lower than those of the simulated models due to the oversize of the experimental compressor. The annual expense of the solar-CAHT was found to be 5113 USD which was lower than 5418 USD of the solar-AHT. So it could be concluded that the modified unit was beneficial than the normal unit in terms of energy efficiency and economic expense. | en_US |
dc.subject | Chemical Engineering | en_US |
dc.subject | Engineering | en_US |
dc.title | Simulation and experimental study of solar-absorption heat transformer integrating with two-stage high temperature vapor compression heat pump | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | Case Studies in Thermal Engineering | en_US |
article.volume | 4 | en_US |
article.stream.affiliations | Maejo University | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.