Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/51877
Title: Impact of patients' positions on the incidence of arrhythmias during pulmonary artery catheterization
Authors: Tanyong Pipanmekaporn
Nutchanart Bunchungmongkol
Pathomporn Pin On
Yodying Punjasawadwong
Authors: Tanyong Pipanmekaporn
Nutchanart Bunchungmongkol
Pathomporn Pin On
Yodying Punjasawadwong
Keywords: Medicine
Issue Date: 1-Jun-2012
Abstract: Objective: The complication of cardiac arrhythmias during pulmonary artery catheterization (PAC) may be related to the position of the patient. Therefore, the purpose of this study was to determine the effects of patients' positions on incidence of arrhythmias and the time required to place the pulmonary artery catheter. Design: A prospective, double-blind, randomized, controlled study. Setting: A tertiary university hospital. Participants: One hundred forty patients undergoing elective coronary artery bypass graft surgery. Interventions: Patients were divided into 2 groups. In the study group (n = 70), patients were positioned with their head down at 10° first and then 10° up and tilted right laterally when the PACs were passed from the right atrium to the right ventricle and then the right ventricle to the pulmonary capillary wedge position, respectively. In the control group (n = 70), patients remained in a supine position during pulmonary artery catheterization. Measurement and Main Result: During the catheterization, arrhythmias were recorded and classified into benign (1-3 premature ventricular contractions) and severe (more than 3 premature ventricular contractions or nonsustained ventricular tachycardia). The time for PACs to pass from the right atrium to the right ventricle and the right ventricle to the pulmonary capillary wedge position was measured as T1 and T2, respectively. The incidence of benign arrhythmias between groups was not significantly different (49% for study and 34% for control group, p = 0.196), whereas the incidence of severe arrhythmias was significantly higher in the control group (20% v 5.8%, p = 0.036). The time used for each technique (T1 and T2) in both groups was not significantly different (p = 0.362 and 0.468, respectively). One patient in the study group was excluded because of difficulty in passing the catheter from the right atrium to the right ventricle. Conclusions: Adjusting patients in the head-up and right lateral position while passing the PAC can reduce the incidence of severe arrhythmias, but not in the time taken to place it. This position may have clinical implications, particularly in high-risk patients. © 2012 Elsevier Inc. All rights reserved.
URI: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84861101863&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/51877
ISSN: 15328422
10530770
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.