Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/51586
Full metadata record
DC FieldValueLanguage
dc.contributor.authorEkkarat Boonchiengen_US
dc.contributor.authorKhanita Duangchaemkarnen_US
dc.date.accessioned2018-09-04T06:04:46Z-
dc.date.available2018-09-04T06:04:46Z-
dc.date.issued2012-12-01en_US
dc.identifier.other2-s2.0-84875085558en_US
dc.identifier.other10.1109/BMEiCon.2012.6465497en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84875085558&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/51586-
dc.description.abstractTo assess the iron overload in human tissue especially in the heart of transfusion-dependent thalassemia patients using cardiac magnetic resonance imaging (CMRI) technique has been widely used to evaluate cardiac iron deposition because of its non-invasive procedure. The iron measure from this technique is represent as T2*(T2 Star) value. Cardiac T2*software was developed. The software was measuring T2*value from DICOM image with two algorithm processing components; regions of interest (ROI) identification, and T2*optimization. The software preliminary testing was performed using test cases DICOM image, three times repeating, from both healthy volunteer and thalassemia patient with cardiac iron overload, then compared T2*value with the reference tool (CMRtools with ThalassemiaTools plug-in). Mean T2*value analyzed from healthy volunteer CMRI was 22.36 (±0.94) and 37.10 (±1.62), respectively. While the mean T2*value analyzed from thalassemia patients CMRI was 15.52 (±0.85) and 18.67 (±1.15) in reference software and CMUT2Star software respectively. In conclusion, CMUT2Star produced a higher T2*value than the reference tool. Software has no any errors and no conflict with testing platform. The algorithm in T2*optimization component need to be adjusted in order to produce the accuracy and robust T2*value. ©2012 IEEE.en_US
dc.subjectEngineeringen_US
dc.titleMyocardial iron measurement in thalassemia using cardiac magnetic resonance image processing softwareen_US
dc.typeConference Proceedingen_US
article.title.sourcetitle5th 2012 Biomedical Engineering International Conference, BMEiCON 2012en_US
article.stream.affiliationsChiang Mai Universityen_US
article.stream.affiliationsUniversity of Phayaoen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.