Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/51586
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ekkarat Boonchieng | en_US |
dc.contributor.author | Khanita Duangchaemkarn | en_US |
dc.date.accessioned | 2018-09-04T06:04:46Z | - |
dc.date.available | 2018-09-04T06:04:46Z | - |
dc.date.issued | 2012-12-01 | en_US |
dc.identifier.other | 2-s2.0-84875085558 | en_US |
dc.identifier.other | 10.1109/BMEiCon.2012.6465497 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84875085558&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/51586 | - |
dc.description.abstract | To assess the iron overload in human tissue especially in the heart of transfusion-dependent thalassemia patients using cardiac magnetic resonance imaging (CMRI) technique has been widely used to evaluate cardiac iron deposition because of its non-invasive procedure. The iron measure from this technique is represent as T2*(T2 Star) value. Cardiac T2*software was developed. The software was measuring T2*value from DICOM image with two algorithm processing components; regions of interest (ROI) identification, and T2*optimization. The software preliminary testing was performed using test cases DICOM image, three times repeating, from both healthy volunteer and thalassemia patient with cardiac iron overload, then compared T2*value with the reference tool (CMRtools with ThalassemiaTools plug-in). Mean T2*value analyzed from healthy volunteer CMRI was 22.36 (±0.94) and 37.10 (±1.62), respectively. While the mean T2*value analyzed from thalassemia patients CMRI was 15.52 (±0.85) and 18.67 (±1.15) in reference software and CMUT2Star software respectively. In conclusion, CMUT2Star produced a higher T2*value than the reference tool. Software has no any errors and no conflict with testing platform. The algorithm in T2*optimization component need to be adjusted in order to produce the accuracy and robust T2*value. ©2012 IEEE. | en_US |
dc.subject | Engineering | en_US |
dc.title | Myocardial iron measurement in thalassemia using cardiac magnetic resonance image processing software | en_US |
dc.type | Conference Proceeding | en_US |
article.title.sourcetitle | 5th 2012 Biomedical Engineering International Conference, BMEiCON 2012 | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
article.stream.affiliations | University of Phayao | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.