Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/50738
Full metadata record
DC FieldValueLanguage
dc.contributor.authorImjai Intachaien_US
dc.contributor.authorSuttichai Krisanaprakornkiten_US
dc.contributor.authorPrachya Kongtawelerten_US
dc.contributor.authorSiriwan Ong-Chaien_US
dc.contributor.authorBoonsiva Buranastidpornen_US
dc.contributor.authorEduardo Yugo Suzukien_US
dc.contributor.authorDhirawat Jotikasthiraen_US
dc.date.accessioned2018-09-04T04:44:56Z-
dc.date.available2018-09-04T04:44:56Z-
dc.date.issued2010-02-01en_US
dc.identifier.issn14602210en_US
dc.identifier.issn01415387en_US
dc.identifier.other2-s2.0-77951638995en_US
dc.identifier.other10.1093/ejo/cjp056en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77951638995&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/50738-
dc.description.abstractThe aim of this study was to monitor changes in chondroitin sulphate (CS; WF6 epitope) levels in peri-miniscrew implant crevicular fluid (PMICF) during orthodontic loading.Ten patients (seven males and three females; aged 22.0 ± 3.4 years), who required orthodontic treatment with extraction of all four premolar teeth, participated in the study. Twenty miniscrew implants (used as orthodontic anchorage) were placed, two in each patient, buccally and bilaterally in the alveolar bone between the roots of the maxillary posterior teeth. Sentalloy closed-coil springs (50 g) were used to load the miniscrew implants and to move the maxillary canines distally. During the unloaded period, PMICF samples were collected on days 1, 3, 5, and 7 after miniscrew implant placement and on days 14, 21, 28, and 35 during the loaded period. Clinical mobility assessments of the miniscrew implants were recorded at each visit. The competitive enzyme-linked immunosorbent assay with monoclonal antibody WF6 was used to detect CS (WF6 epitope) levels in the PMICF samples. The differences between the CS (WF6 epitope) levels during the unloaded and loaded periods were determined by a Mann-Whitney U-test.During the loaded period, two miniscrew implants were considered to have failed. The CS (WF6 epitope) levels during the unloaded period ranged from 0.00 to 758.03 ng/ml and those during the loaded period from 0.00 to 1025.11 ng/ml. Medians of CS (WF6 epitope) levels, around 'immobile' miniscrew implants, between the unloaded and loaded periods were not significantly different (P=0.07).CS (WF6 epitope) levels in PMICF can be detected and may be used as biomarkers for assessing alveolar bone remodelling around miniscrew implants during orthodontic loading. © The Author 2008. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved.en_US
dc.subjectDentistryen_US
dc.titleChondroitin sulphate (WF6 epitope) levels in peri-miniscrew implant crevicular fluid during orthodontic loadingen_US
dc.typeJournalen_US
article.title.sourcetitleEuropean Journal of Orthodonticsen_US
article.volume32en_US
article.stream.affiliationsChiang Mai Universityen_US
article.stream.affiliationsFaculty of Dentistryen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.