Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/50204
Full metadata record
DC FieldValueLanguage
dc.contributor.authorChanane Wanapiraken_US
dc.contributor.authorWirawit Piyamongkolen_US
dc.contributor.authorSupatra Sirichotiyakulen_US
dc.contributor.authorChatchai Tayapiwatanaen_US
dc.contributor.authorWatchara Kasinrerken_US
dc.contributor.authorTheera Tongsongen_US
dc.date.accessioned2018-09-04T04:26:28Z-
dc.date.available2018-09-04T04:26:28Z-
dc.date.issued2011-07-01en_US
dc.identifier.issn01252208en_US
dc.identifier.other2-s2.0-79960065272en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79960065272&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/50204-
dc.description.abstractObjective: To determine the accuracy of alpha-Thal Immunochromatographic (IC) strip in diagnosis of alpha-thalassemia 1 carrier among pregnant women, using PCR for alpha-thalassemia 1 (SEA type) as a gold standard. Material and Method: Asymptomatic pregnant women attending the antenatal care clinic were recruited. Their blood samples were taken for IC Strip Test (α Thal IC strip, i+Med Laboratories Company Limited) in predicting alpha-thalassemia 1 carrier and separately sent for PCR for diagnosis of α-thalassemia 1 carrier as a gold standard. Results: Four hundred ninety nine pregnant women were recruited into the present study at various gestational weeks. The accuracy of alpha-Thal IC strip test was relatively high as shown in Table 1. Of them, 62 cases were proven to be alphathalassemia 1 trait and all of them had the results of positive IC strip, giving a sensitivity of 100%. However, 45 pregnant women of non-α-thalassemia 1 trait had positive test, giving a specificity of 89%. Conclusion: The present study was solid evidence for clinical application of α-thal IC strip in screening program of thalassemia to reduce the need for PCR in diagnosis of α-thalassemia 1 carrier because of its very high sensitivity. The negative test reassures the non α-thalassemia 1 carrier status. Moreover, due to its simplicity, convenience to use, low cost, less-time consuming, clear interpretation and no need for either equipment or expensive laboratories, it may probably be very helpful in a massive screening program.en_US
dc.subjectMedicineen_US
dc.titleAccuracy of immunochromatographic strip test in diagnosis of alpha-thalassemia-1 carrieren_US
dc.typeJournalen_US
article.title.sourcetitleJournal of the Medical Association of Thailanden_US
article.volume94en_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.