Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/77385
Full metadata record
DC FieldValueLanguage
dc.contributor.authorS. Wongkeen_US
dc.contributor.authorL. D. Yuen_US
dc.contributor.authorU. Tippawanen_US
dc.date.accessioned2022-10-16T07:29:32Z-
dc.date.available2022-10-16T07:29:32Z-
dc.date.issued2021-01-28en_US
dc.identifier.issn17426596en_US
dc.identifier.issn17426588en_US
dc.identifier.other2-s2.0-85100702269en_US
dc.identifier.other10.1088/1742-6596/1719/1/012055en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85100702269&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/77385-
dc.description.abstractIn our practice of applying GUPIXWIN software in calculations of the trace element concentrations in biosamples measured by particle induced X-ray emission (PIXE) technique, we found that the calculated concentration data critically depended on the program setup and experimental parameters input to the software. Dependences on some important setups and parameters such as the solution types (i.e. Trace element solution in a known matrix and Iterative matrix element solution), matrix composition, detector parameters (e.g. window thickness), sample structure, normalization, etc., which are sometimes easily not paid with intensive attention by users, are analyzed and discussed utilizing our PIXE spectra of some biosamples. We found that most parameters or program setups were critical to affect the calculated results, but some such as normalization was not. We also found that if only relative trace element concentrations instead of their absolute values are concerned, different program setup solutions resulted in similar data. We conclude that meticulous care must be taken in selection of the experimental parameters and setup conditions in using GUPIXWIN to make correct calculations of the trace element concentrations in biological or organic samples.en_US
dc.subjectPhysics and Astronomyen_US
dc.titleProgram setup and parameter dependences of GUPIXWIN-calculated trace element concentration measured by PIXE analysisen_US
dc.typeConference Proceedingen_US
article.title.sourcetitleJournal of Physics: Conference Seriesen_US
article.volume1719en_US
article.stream.affiliationsMinistry of Higher Education, Science, Research and Innovationen_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.