Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/77200
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAnupong Kongsaen_US
dc.contributor.authorImjai Chitapanaruxen_US
dc.contributor.authorAnirut Watcharawiphaen_US
dc.contributor.authorLalita Huntrakulen_US
dc.contributor.authorWarit Thongsuken_US
dc.contributor.authorPitchayaponne Klunklinen_US
dc.date.accessioned2022-10-16T07:24:37Z-
dc.date.available2022-10-16T07:24:37Z-
dc.date.issued2021-01-01en_US
dc.identifier.issn14671131en_US
dc.identifier.issn14603969en_US
dc.identifier.other2-s2.0-85113803296en_US
dc.identifier.other10.1017/S1460396921000431en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85113803296&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/77200-
dc.description.abstractAim: To propose a new matching method for the supraclavicular (SC) and tangential fields on three-dimensional radiotherapy (3DRT) for postmastectomy radiotherapy (PMRT). Methods: A method of matching coplanar field borders (CFB) between the tangential and SC fields was created in 3DRT. The collimator angle of the medial tangential field was calculated to coplanar the SC field. The proposed method performance was ultimately benchmarked using the half beam block (HBB) and traditional three-field monoisocenter (TTM) methods by dosimetric comparison. The decision score was then employed to clarify the performance among these methods. Results: The results show that the TTM method exhibited not only low doses on the organs at risk (OAR) but also on the matching fields. The CFB and HBB produced comparable results, but the ipsilateral lung yielded lesser amounts than the HBB. The decision score indicated a low performance level when using the TTM method, whereas the CBF method exhibited a slightly higher performance score than the HBB. Findings: The CFB exhibited good performance in terms of the dose on OARs and at the matching fields. This method offers a comparable level of performance to the HBB. Thus, the CFB offers an alternative method of significant interest in PMRT.en_US
dc.subjectMedicineen_US
dc.titleImprovement of matching fields using coplanar field border method in postmastectomy radiotherapyen_US
dc.typeJournalen_US
article.title.sourcetitleJournal of Radiotherapy in Practiceen_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.