Title: Portable dynamic ultrasonography is a useful tool for the evaluation of suspected syndesmotic instability: a cadaveric study
Authors: N. C. Hagemeijer
B. Lubberts
J. Saengsin
R. Bhimani
G. Sato
G. R. Waryasz
G. M.M.J. Kerkhoffs
C. W. DiGiovanni
D. Guss
Authors: N. C. Hagemeijer
B. Lubberts
J. Saengsin
R. Bhimani
G. Sato
G. R. Waryasz
G. M.M.J. Kerkhoffs
C. W. DiGiovanni
D. Guss
Keywords: Medicine
Issue Date: 1-Jan-2022
Abstract: Purpose: Portable ultrasonography (P-US) is increasingly used to diagnose syndesmotic instability. The aim of this study was to evaluate syndesmotic instability by measuring the distal tibiofibular clear space (TFCS) in a cadaveric model using P-US with progressive stages of syndesmotic ligamentous transection under external rotation stress. Methods: Ten fresh lower leg cadaveric specimens amputated above the proximal tibiofibular joint were used. Using P-US, the TFCS was evaluated in the intact stage and after progressive sectioning of the (1) anterior–inferior tibiofibular ligament (AITFL), (2) interosseous ligament (IOL), and (3) posterior–inferior tibiofibular ligament (PITFL). The TFCS was measured in both the unstressed (0 Nm) state and with 4.5, 6.0, 7.5, and 9.0 Nm of external rotation stress using a bone hook placed on the first metatarsal bone at each stage of ligamentous transection stage using both P-US and fluoroscopy. Results: When assessed with P-US, partial syndesmotic injury encompassing the AITFL and IOL resulted in significant TFCS widening at 4.5 Nm of external rotation torque when compared to intact state with a TFCS-opening of 2.6 ± 2 mm, p = 0.01. In contrast, no significant differences in TFCS were detected using fluoroscopy. Only a moderate correlation was found between P-US and fluoroscopy. Conclusion: P-US is a useful tool in diagnosing syndesmotic instability during external rotation stress examination. TFCS-opening increased as additional ligaments of the syndesmosis were transected, and application of 4.5 Nm torque was sufficient to detect a difference of 2.6 mm after the IOL cut.
URI: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85134742058&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/76153
ISSN: 14337347
09422056
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.