Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/76122
Full metadata record
DC FieldValueLanguage
dc.contributor.authorWongthawat Liawrungrueangen_US
dc.contributor.authorK. Daniel Riewen_US
dc.contributor.authorNantawit Sugandhavesaen_US
dc.contributor.authorTorphong Bunmapraserten_US
dc.date.accessioned2022-10-16T07:05:50Z-
dc.date.available2022-10-16T07:05:50Z-
dc.date.issued2022-01-01en_US
dc.identifier.issn14320932en_US
dc.identifier.issn09406719en_US
dc.identifier.other2-s2.0-85138293154en_US
dc.identifier.other10.1007/s00586-022-07385-7en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85138293154&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/76122-
dc.description.abstractPurpose: To compare the Atlas (C1) lateral mass screw placement between screw trajectories of 0° and 15° medial angulation while using the intersection between lateral mass and inferomedial edge of the posterior arch. Methods: Forty-eight Atlas lateral masses were prepared and divided into 2 groups: Group 1; screws inserted at 3 mm lateral to the reference point with screw trajectory of 0° angulation(N = 24) and Group 2; those inserted with screw trajectory of 15° medial angulation(N = 24). We evaluated the atlas anatomy, screw purchase and the presence of any breaches using CT scan. Results: The radiographic parameters for Groups 1 and 2 were found statistically different (p-value < 0.05): bilateral intraosseous screw lengths (17.92 ± 1.47 mm. vs. 20.71 ± 2.4 mm.), bilateral screw length (29.92 ± 1.72 mm. vs. 33.13 ± 1.78 mm.), left screw medial angulation (x°) (0.67° ± 0.78° vs.14.17° ± 3.51°), right screw medial angulation (y°) (0.83° ± 1.03° vs.14.25° ± 2.53°) and bilateral screw medial angulation (0.75° ± 0.9° vs. 14.21° ± 2.99°). Twenty-two screws (91.67%) using the 0° medial angulation and nineteen screws (79.17%) using the 15° medial angulation had no cortical violations (Grade 0). However, two screws (8.33%) with 0° medial angulation and five screws (20.83%) with 15° medial angulation had breach less than 2 mm (Grade 1). There were no screws with breach between 2 and 4 mm (Grade 2) or greater than 4 mm. (Grade 3). Conclusion: A starting point of 3-mm lateral to the intersection between lateral mass and inferomedial edge of the Atlas posterior arch can be safely and effectively used to insert C1 lateral mass using both 0° and 15° medial angulation.en_US
dc.subjectMedicineen_US
dc.titleAtlas (C1) lateral mass screw placement using the intersection between lateral mass and inferomedial edge of the posterior arch: a cadaveric studyen_US
dc.typeJournalen_US
article.title.sourcetitleEuropean Spine Journalen_US
article.stream.affiliationsUniversity of Phayaoen_US
article.stream.affiliationsFaculty of Medicine, Chiang Mai Universityen_US
article.stream.affiliationsColumbia Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.