Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/75825
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Thidarat Kruatian | en_US |
dc.contributor.author | Kritsana Jitmanee | en_US |
dc.contributor.author | Jaroon Jakmunee | en_US |
dc.date.accessioned | 2022-10-16T07:02:56Z | - |
dc.date.available | 2022-10-16T07:02:56Z | - |
dc.date.issued | 2021-01-01 | en_US |
dc.identifier.issn | 01252526 | en_US |
dc.identifier.other | 2-s2.0-85104957900 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85104957900&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/75825 | - |
dc.description.abstract | A flow injection (FI) system with amperometric detection has been proposed for the determination of iodine value (IV) of vegetable oils. An aliquot of a sample of 0.010-g was treated with 1.00 mL of Hanus solution for 1 minute before adding with potassium iodide solution to generate tri-iodide. Then, the solution was injected into the FI-amperometric system to detect the tri-iodide by using a screen-printed carbon electrode (SPCE) at an applied potential of 750 mV (vs Ag/AgCl). The system was optimized to provide high sensitivity by utilizing various concentration of Hanus solutions for constructing a calibration graph, which was linear in a range of 40-100 µM (r2 = 0.997) with limit of detection of 3.6 IV. An injection frequency of 60 h-1 was achieved by using 2.5 mL/min flow rate. A good repeatability of injection (0.20-0.58 %RSD, n=11) and good reproducibility for replicated analysis of 5 aliquots of a sample (1.07-1.36 %RSD) were demonstrated. The proposed method was successfully applied to vegetable oil samples with low to high iodine value. The proposed method offers high sample throughput and low reagent consumption. | en_US |
dc.subject | Biochemistry, Genetics and Molecular Biology | en_US |
dc.subject | Chemistry | en_US |
dc.subject | Materials Science | en_US |
dc.subject | Mathematics | en_US |
dc.subject | Physics and Astronomy | en_US |
dc.title | Flow injection system with amperometric detection for determination of iodine value of vegetable oils | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | Chiang Mai Journal of Science | en_US |
article.volume | 48 | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.