Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/75601
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Piyanat Issarangkura Na Ayutthaya | en_US |
dc.contributor.author | Chonnipa Yeerum | en_US |
dc.contributor.author | Kullapon Kesonkan | en_US |
dc.contributor.author | Kanokwan Kiwfo | en_US |
dc.contributor.author | Kate Grudpan | en_US |
dc.contributor.author | Norio Teshima | en_US |
dc.contributor.author | Hiroya Murakami | en_US |
dc.contributor.author | Monnapat Vongboot | en_US |
dc.date.accessioned | 2022-10-16T07:01:08Z | - |
dc.date.available | 2022-10-16T07:01:08Z | - |
dc.date.issued | 2021-08-01 | en_US |
dc.identifier.issn | 14203049 | en_US |
dc.identifier.other | 2-s2.0-85111355895 | en_US |
dc.identifier.other | 10.3390/molecules26154397 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85111355895&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/75601 | - |
dc.description.abstract | A simple flow injection FlameAAS for lead determination with an alginate-polyurethane composite (ALG-PUC) monolithic in-valve column has been developed. The ALG-PUC monolithic rod was prepared by mixing methylene diphenyl diisocyanate with polyol and sodium alginate with the ratio of 2:1:1 by weight for a 5 min polymerization reaction. It was then put into a column (0.8 cm i.d × 11 cm length) situated in a switching valve for the FI set up. A single standard calibration could be obtained by plotting the loaded µg Pb2+ vs. FI response (absorbances). The loaded µg Pb2+ is calculated: μg Pb2+ = FRload × LT × CPb2+, where the FRload is the flow rate of the loading analyte solution (mL min−1), LT is the loading time (min), and CPb2+ is the Pb2+ concentration (µg mL−1). A linear calibration equation was obtained: FI response (absorbances) = 0.0018 [µg Pb2+] + 0.0032, R2 = 0.9927 for 1-150 µg Pb2+, and RSD of less than 20% was also obtained. Application of the developed procedure has been demonstrated in real samples. | en_US |
dc.subject | Biochemistry, Genetics and Molecular Biology | en_US |
dc.subject | Chemistry | en_US |
dc.subject | Pharmacology, Toxicology and Pharmaceutics | en_US |
dc.title | Determination of lead employing simple flow injection AAS with monolithic alginate-polyurethane composite packed in-valve column | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | Molecules | en_US |
article.volume | 26 | en_US |
article.stream.affiliations | Aichi Institute of Technology | en_US |
article.stream.affiliations | King Mongkut's University of Technology Thonburi | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.