Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/73383
Full metadata record
DC FieldValueLanguage
dc.contributor.authorApinya Obmaen_US
dc.contributor.authorPattamaporn Hemwechen_US
dc.contributor.authorSittisak Phoolphoen_US
dc.contributor.authorRawiwan Bumrungpuechen_US
dc.contributor.authorSupa Wirasateen_US
dc.contributor.authorSulawan Kaowphongen_US
dc.contributor.authorPrapin Wilairaten_US
dc.contributor.authorRattikan Chantiwasen_US
dc.date.accessioned2022-05-27T08:40:44Z-
dc.date.available2022-05-27T08:40:44Z-
dc.date.issued2022-12-01en_US
dc.identifier.issn20452322en_US
dc.identifier.other2-s2.0-85129693882en_US
dc.identifier.other10.1038/s41598-022-11078-yen_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85129693882&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/73383-
dc.description.abstractA hydrothermal sol–gel method for reproducible formation of silica nanolayer on the wall of silica capillaries was developed for electrochromatography. The formulation was optimized by observation of uniform gel formation on an optical microscope. The variables of the formulation include types of solvent, water-TEOS ratio, CTAB and urea contents, and mixing method. The procedure produced a coating of silica ca. 100 nm thick layer on the wall of the capillary. Surface morphology of the coating was characterized by SEM, contact angle and chemical composition by FT-IR spectroscopy and X-ray powder diffraction. The coating reduced the electroosmotic mobility producing enhanced separation performance. Eight standard amines (including tyramine and benzhydrylamine, as an internal standard) were separated with peak resolution Rs ≥ 2 for all adjacent peaks and plate number N ≥ 3.0 × 104 m-1. Calibration was linear from 5 to 200 µg L-1, with r2 > 0.9985 and instrumental LOD of 4.9 μg L-1. Five samples of food products were diluted and analyzed for the amines using the coated capillary and only tyramine was detected. Intra-day and inter-day precisions were less than 1.2%RSD. Percent recoveries of spiked tyramine in samples were 95 ± 3 to 106 ± 7% (n = 3).en_US
dc.subjectMultidisciplinaryen_US
dc.titleSilica nanolayer coated capillary by hydrothermal sol–gel process for amines separation and detection of tyramine in food productsen_US
dc.typeJournalen_US
article.title.sourcetitleScientific Reportsen_US
article.volume12en_US
article.stream.affiliationsMahidol Universityen_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.