Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/72988
Title: Innovative utilization of compact disc for measuring fast neutron generated from a 10 MV medical linear accelerator
Authors: Porama Thepsiri
Phiphat Phruksarojanakun
Natch Rattanarungruangchai
Thiti Rungseesumran
Tanapol Dachviriyakij
Chayanit Jumpee
Authors: Porama Thepsiri
Phiphat Phruksarojanakun
Natch Rattanarungruangchai
Thiti Rungseesumran
Tanapol Dachviriyakij
Chayanit Jumpee
Keywords: Health Professions
Issue Date: 1-Jan-2022
Abstract: Background: High-energy photons produced from a medical linear accelerator (LINAC) have long been used as one of the most effective ways for treating cancers. During the treatment process, some photo neutrons are unavoidably created by [γ,n] reactions, imposing additional and undesirable dose on a patient. This amount of unplanned dose from photo neutrons can potentially harm the patient as well as medical personnel during the treatment. Objectives: To develop a methodology for measuring fast neutron dose generated from 10 MV LINAC by employing polycarbonate from base material of compact disk (CDs) and a fast neutron converter. Materials and methods: The polycarbonate base layer of CDs has been applied to fast neutron dosimetry with nuclear track method by combining with polymethyl methacrylate (PMMA) converter for fast neutrons. A number of CDs badges were irradiated with high energy photon from 10 MV Elekta Synergy LINAC in the solid water phantom at depth of 0, 2.5, 5, 10, 15 and 20 cm then etched with potassium hydroxide ethanol water (PEW) solution that containing with potassium hydroxide, ethanol and water with ratio of 15:45:40. The optimal condition for the chemical etching were found at 60±2 °C, for 14 hr. Results: Comparison of neutron equivalent doses from measurement of CD track detector and CR-39 track detector has shown that the maximum fast neutron dose equivalent was at depth of 5 cm of phantom. This agreement has confirmed that the CD track detector can be employed to measure fast neutron doses produced from LINAC in an accurate and affordable fashion. Conclusion: It is confirmed that the CD track detector can be employed to measure fast neutron doses produced from LINAC in an accurate and affordable fashion.
URI: https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85124833453&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/72988
ISSN: 25396056
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.