Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/70356
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Wasin Somboot | en_US |
dc.contributor.author | Jaroon Jakmunee | en_US |
dc.contributor.author | Tinakorn Kanyanee | en_US |
dc.date.accessioned | 2020-10-14T08:28:17Z | - |
dc.date.available | 2020-10-14T08:28:17Z | - |
dc.date.issued | 2020-12-01 | en_US |
dc.identifier.issn | 0026265X | en_US |
dc.identifier.other | 2-s2.0-85091748719 | en_US |
dc.identifier.other | 10.1016/j.microc.2020.105555 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85091748719&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/70356 | - |
dc.description.abstract | © 2020 An environmentally friendly modified flow analysis carrier with a high refractive index liquid to perform a total internal refrection phenomenon in a typical Teflon tube was achieved as a cost-effective long-path liquid core waveguide (LCW) for absorption spectrophotometry. A home-built LED-photodiode based long-path colorimeter was demonstrated to enhance the sensitivity of chemical analysis without using a preconcentration unit. A low toxicity carrier such as syrup or ethanol was selected to improve the sensitivity for NH4+ ion determination via butterfly pea flower extract reagent in a gas-diffusion flow injection (GD-FI) system. A linear calibration range of NH4+ ion determination in the GD-FI based on syrup modified LCW (mLCW) system of 10–500 µmol L−1 can be obtained with a detection limit of 9.8 µmol L−1, repeatability of <2% RSD, and 12 injections h−1 sample throughput. The proposed cost-effective and environmentally friendly mLCW shows the potential to apply with other natural/synthetic chromogenic reagents for the green chemical analysis approach. | en_US |
dc.subject | Chemistry | en_US |
dc.title | Environmentally friendly liquid medium for a cost-effective long-path absorption liquid core waveguide with a gas diffusion flow analysis system | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | Microchemical Journal | en_US |
article.volume | 159 | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.