dc.description.abstract© 2019 ICE Publishing. All rights reserved. Substantial damage to buildings from seismic pounding is the result of earthquakes in many urban areas. This study investigated the effects of pounding in low-rise buildings, which had been individually designed for seismic resistance, using a three-dimensional numerical model. The pounding between the heavier and lighter buildings was conducted for four cases with floor to floor collision and zero separation gap; the total heights of the buildings were varied. The ratio of the storey mass between the heavier to the lighter buildings in all cases was 1.7. The results demonstrated that the heavier buildings were almost unaffected by the collision, and that seismic design without consideration of pounding is acceptable. However, the pounding had more influence on lighter buildings. A significant increase of inter-storey drift and the storey shear force was found. At the top floor of the lighter building, the inter-storey drift and the storey shear force were increased in the range of 35-73% and 20-46%, respectively, compared with no-pounding events. In addition, severe damage at beam-column joints was found. Hence, lighter buildings require special attention during a seismic pounding event.en_US
dc.subjectEngineeringen_US
dc.titlePounding of seismically designed low-rise reinforced concrete framesen_US
dc.typeJournalen_US
article.title.sourcetitleProceedings of the Institution of Civil Engineers: Structures and Buildingsen_US
article.volume172en_US
article.stream.affiliationsCurtin Universityen_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.