Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/67539
Full metadata record
DC FieldValueLanguage
dc.contributor.authorWorapaka Manosroien_US
dc.contributor.authorMattabhorn Phimphilaien_US
dc.contributor.authorJiraporn Khoranaen_US
dc.contributor.authorPichitchai Atthakomolen_US
dc.date.accessioned2020-04-02T14:55:24Z-
dc.date.available2020-04-02T14:55:24Z-
dc.date.issued2019-01-01en_US
dc.identifier.issn19326203en_US
dc.identifier.other2-s2.0-85075178658en_US
dc.identifier.other10.1371/journal.pone.0225255en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85075178658&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/67539-
dc.description.abstract© 2019 Manosroi et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Objective An ACTH stimulation test is the standard diagnostic test for adrenal insufficiency (AI). We aimed to investigate the diagnostic performance between serum morning (0800 h) cortisol and serum basal (0900-1300 h) cortisol levels and determine the proper cut-off point to facilitate AI diagnosis to reduce the number of tests. Methods A six-year retrospective study was performed in a tertiary care medical center. We identified 416 patients who had undergone either low (LDT) or high dose (HDT) ACTH stimulation outpatient tests. AI was defined as a peak serum cortisol level of <500 nmol/L at 30 or 60 minutes after LDT or HDT. The associations between AI and serum basal and morning cortisol levels were demonstrated by logistic regression model. Diagnostic performance was evaluated by ROC analysis. Results Of the 416 patients, 93 (22.4%) were categorized as having AI. The adjusted area under the curve (AUC) for the basal cortisol level for the diagnosis of AI was significantly higher than that for the morning cortisol (0.82 vs 0.69, p <0.001) level. The proposed cut-off values for the basal cortisol were <85 nmol/L (specificity 99.7%) and >350 nmol/L(sensitivity 98.9%). By using these proposed cut-off points, approximately 30% of the ACTH stimulation tests could be eliminated. Conclusion The serum basal cortisol level with the proposed cut-off points were considered as an alternative option for diagnosis of AI. Utilizing the serum basal cortisol level can facilitate AI diagnosis as it is convenient, is not a time-specific test and has a high diagnostic performance.en_US
dc.subjectAgricultural and Biological Sciencesen_US
dc.subjectBiochemistry, Genetics and Molecular Biologyen_US
dc.subjectMultidisciplinaryen_US
dc.titleDiagnostic performance of basal cortisol level at 0900-1300h in adrenal insufficiencyen_US
dc.typeJournalen_US
article.title.sourcetitlePLoS ONEen_US
article.volume14en_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.