Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/67342
Title: Comparison Between Linear and Non-linear Variable Selection Methods with Applications to Spectroscopic (UV-Vis/NIR) Data
Authors: Chanida Krongchai
Sakunna Wongsaipun
Sujitra Funsueb
Parichat Theanjumpol
Jaroon Jakmunee
Sila Kittiwachana
Authors: Chanida Krongchai
Sakunna Wongsaipun
Sujitra Funsueb
Parichat Theanjumpol
Jaroon Jakmunee
Sila Kittiwachana
Keywords: variable selection;multivariate calibration;partial least squares (PLS);elf organizing map (SOM);spectral data analysis
Issue Date: 2020
Publisher: Science Faculty of Chiang Mai University
Citation: Chiang Mai Journal of Science 47, 1 (January 2020), 160-174
Abstract: Variable selection aims to identify important parameters in relation to predicted responses. Selection outcomes of the important variables could be different depending on the methods used. In this research, the important variables identified using linear and non-linear variable selection methods based on partial least squares-variable important in prediction (PLS-VIP) and self organizing mapdiscrimination index (SOM-DI) were compared. Two datasets, near-infrared (NIR) spectra of adulterated Thai Jasmine rice and ultraviolet-visible (UV-Vis) spectra of food colorant mixtures were used for the demonstration. The advantages and disadvantages for the use of the different algorithms were compared and discussed. For the NIR data, the calibration model using supervised self organizing map (SSOM) offered better prediction results and the SOM-DI variable selection method identified the spectral changes in NIR overtone regions as significance. On the other hand, PLS calibration model resulted in higher predictive errors while the PLS-VIP variable selection captured variation from the visible region between 664 nm and 884 nm. Using the UV-Vis data, PLS appeared to put attention on only the highest absorbance region of the peak maximum absorbance. In contrast, SSOM model highlighted the variation around the isosbestic spectral regions between the mixture components. The drawback for the use of a mixture design to construct the calibration models, leading to wrong interpretation of the important variables, was also discussed.
URI: http://epg.science.cmu.ac.th/ejournal/dl.php?journal_id=10583
http://cmuir.cmu.ac.th/jspui/handle/6653943832/67342
ISSN: 0125-2526
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.