Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/66644
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAttakorn Charatchaiwannaen_US
dc.contributor.authorThaned Rojsiraphisaen_US
dc.contributor.authorWeerapan Aunmeungtongen_US
dc.contributor.authorPeter A. Reicharten_US
dc.contributor.authorPathawee Khongkhunthianen_US
dc.date.accessioned2019-09-16T12:51:08Z-
dc.date.available2019-09-16T12:51:08Z-
dc.date.issued2019-01-01en_US
dc.identifier.issn17088208en_US
dc.identifier.issn15230899en_US
dc.identifier.other2-s2.0-85070087875en_US
dc.identifier.other10.1111/cid.12828en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85070087875&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/66644-
dc.description.abstract© 2019 Wiley Periodicals, Inc. Background: Total stability of dental implant can be obtained from resonance frequency analysis (RFA) device, but without primary and secondary stability values. Purpose: To formulate mathematical equations for dental implant stability patterns during the osseointegration period. Materials and Methods: An online systematically search of the literature between January 1996 and December 2017 was performed for all prospective clinical trials that measured implant stability using RFA device during the osseointegration period. Initial mathematical function with adjustable parameters were created. Then curve-fitting was performed using a computerized program to formulate mathematical equations stability patterns. Results: Nine publications (24 study groups) were included in the mathematical analysis. Curve fitting with low sum of squared errors could be applied in all studies, except one. The stability has been divided into high, medium, and low stability. The curve fitting showed stability dip areas and intersection point which predict the returning of the stability to reach the primary stability. The study groups with low primary stability showed the poorest results, the high and medium stability group showed the stability pattern following the assumed primary stability pattern according to the mathematic equations. Conclusions: The model of primary and secondary stability could be predicted from the proposed equations.en_US
dc.subjectDentistryen_US
dc.titleMathematical equations for dental implant stability patterns during the osseointegration period, based on previous resonance frequency analysis studiesen_US
dc.typeJournalen_US
article.title.sourcetitleClinical Implant Dentistry and Related Researchen_US
article.stream.affiliationsCharité – Universitätsmedizin Berlinen_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.