Please use this identifier to cite or link to this item: http://cmuir.cmu.ac.th/jspui/handle/6653943832/66616
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDuangruedee Dissanguanen_US
dc.contributor.authorPatraporn Sitilertpisanen_US
dc.contributor.authorSuchart Kiatwattanacharoenen_US
dc.contributor.authorLeonard H. Josephen_US
dc.contributor.authorPinyo Puangmalien_US
dc.contributor.authorAatit Paungmalien_US
dc.date.accessioned2019-09-16T12:49:11Z-
dc.date.available2019-09-16T12:49:11Z-
dc.date.issued2019-01-01en_US
dc.identifier.issn18741207en_US
dc.identifier.other2-s2.0-85070674372en_US
dc.identifier.other10.2174/1874120701913010067en_US
dc.identifier.urihttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85070674372&origin=inwarden_US
dc.identifier.urihttp://cmuir.cmu.ac.th/jspui/handle/6653943832/66616-
dc.description.abstract© 2019 Dissanguan et al. All rights reserved. Background: Core muscle activation is an effective intervention for the management of Low Back Pain (LBP). This study developed new feedback for detecting activation of the transversus abdominis muscle in the lumbar spine. The purpose of this study was to examine the validity and reliability of the feedback device for transversus abdominis muscle contraction. Methods: The participants in this study were 20 healthy males and females (aged 24.1 ± 6.8 years). The feedback sensor was attached to the lumbar support at the front of the trunk. The participants performed an abdominal drawing-in maneuver in order to activate the transversus abdominis muscle, and values from the feedback sensor were collected at the same time. Ultrasound imaging of the transversus abdominis muscle was also collected simultaneously. The feedback sensor collected values at different clinical levels of the pressure biofeedback unit at 64, 66, 68, and 70 mmHg. The protocol was repeated with a 24-hr interval. Intra-class correlation coefficient, coefficient of variation and standard error of measurements were used to examine reliability. The validity of the values obtained from the relationship between the feedback sensor and transversus abdominis muscle thickness was analyzed using Pearson s correlation coefficients. Results: Test retest reliability of the feedback sensor was excellent (ICC = 0.946, CV = 2.6%, SEMs = 0.54%). Values of the feedback sensor reported a significantly moderate correlation with the gold standard ultrasound measurement (r = - 0.514, p < 0.001). Conclusion: The feedback device demonstrated potential reliability and validity for clinical use by indicating activation of the transversus abdominis muscle.en_US
dc.subjectChemical Engineeringen_US
dc.subjectEngineeringen_US
dc.subjectMedicineen_US
dc.titleReliability and validity of the feedback sensor for activating the transversus abdominis muscleen_US
dc.typeJournalen_US
article.title.sourcetitleOpen Biomedical Engineering Journalen_US
article.volume13en_US
article.stream.affiliationsUniversity of Brightonen_US
article.stream.affiliationsChiang Mai Universityen_US
Appears in Collections:CMUL: Journal Articles

Files in This Item:
There are no files associated with this item.


Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.