Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/66123
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lida Beheshti-Maal | en_US |
dc.contributor.author | Latifeh Navidpour | en_US |
dc.contributor.author | Minoo Afshar | en_US |
dc.date.accessioned | 2019-08-21T09:18:22Z | - |
dc.date.available | 2019-08-21T09:18:22Z | - |
dc.date.issued | 2016 | en_US |
dc.identifier.citation | Chiang Mai Journal of Science 43, 3 (Apr 2016), 621 - 630 | en_US |
dc.identifier.issn | 0125-2526 | en_US |
dc.identifier.uri | http://it.science.cmu.ac.th/ejournal/dl.php?journal_id=6821 | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/66123 | - |
dc.description.abstract | A green and stability-indicating RP-HPLC method was developed for determination of dapsone in pharmaceutical preparations. The separation was based on a C18 analytical column. The mobile phase consisted of formic acid solution (pH =3):ethanol (90:10, v/v). In forced degradation studies, the drug was subjected to oxidation, hydrolysis, photolysis and heat. Among the different stress conditions, the exposure to light (UV-C and sunlight) was found to be an important adverse stability factor. The drug exhibited degradation in both irradiation experiments affording a common photoproduct. The applied procedure was found to be linear in concentration range of 0.2-50 µg/mL (r2= 0.9999). Precision was evaluated by replicate analysis in which % relative standard deviation values for areas were found to be below 2.0. The recoveries obtained (99.50-101.38%) ensured the accuracy of the developed method. The peak of dapsone was well resolved from the photoproduct as well as the pharmaceutical excipients. Accordingly, the proposed validated and sustainable procedure was proved to be proper for routine analyzing and stability studies of dapsone in pharmaceutical formulations. | en_US |
dc.language.iso | Eng | en_US |
dc.publisher | Science Faculty of Chiang Mai University | en_US |
dc.subject | dapsone | en_US |
dc.subject | photoproduct | en_US |
dc.subject | green analytical chemistry | en_US |
dc.subject | aniline | en_US |
dc.title | An Ecofriendly and Stability-indicating RP-HPLC Method for Determination of Dapsone: Application to Pharmaceutical Analysis | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.